Optimization of Transient Control Parameters of Renewable Energy Considering Power Angle Stability and Over‐Voltage in the Power Generation Base

ABSTRACT Coupling renewable energy with conventional energy sources for power transmission is an effective approach to improving the absorption capacity of renewable energy. However, the issues of transient angle instability and over‐voltage are key factors limiting the external transmission capacity of the power corridor. First, an equivalent power angle characteristic equation for a renewable energy‐thermal power coupling generation system is established to analyse the impact of transient control parameters on transient power angle stability. Second, a mathematical analysis of terminal voltage of the renewable energy machine is conducted to explore the influence of transient control parameters on the terminal voltage. Third, optimization principles for transient control parameters of renewable energy are proposed. Finally, a case study of athermal power‐renewable energycoupled generation base is presentedand the effectiveness of the proposedmethod is validated through time‐domain simulations.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2025-01-01
DOI
https://doi.org/10.1049/gtd2.70124
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Transient Control Parameters of Renewable Energy Considering Power Angle Stability and Over‐Voltage in the Power Generation Base

Yongli Zhu, Yang Yuxin, Jian Wu, Jinsong Wang et al.
IET Generation Transmission & Distribution
Power Systems and Renewable Energy
article

Optimization of Transient Control Parameters of Renewable Energy Considering Power Angle Stability and Over‐Voltage in the Power Generation Base

Yongli Zhu, Yang Yuxin, Jian Wu, Jinsong Wang, Haichao Yang
article en

Abstract

ABSTRACT Coupling renewable energy with conventional energy sources for power transmission is an effective approach to improving the absorption capacity of renewable energy. However, the issues of transient angle instability and over‐voltage are key factors limiting the external transmission capacity of the power corridor. First, an equivalent power angle characteristic equation for a renewable energy‐thermal power coupling generation system is established to analyse the impact of transient control parameters on transient power angle stability. Second, a mathematical analysis of terminal voltage of the renewable energy machine is conducted to explore the influence of transient control parameters on the terminal voltage. Third, optimization principles for transient control parameters of renewable energy are proposed. Finally, a case study of athermal power‐renewable energycoupled generation base is presentedand the effectiveness of the proposedmethod is validated through time‐domain simulations.

IET Generation Transmission & DistributionVol. 19(1)
North China Electric Power University (CN), China Datang Corporation (China) (CN)
Openalex Percentile: Top 83%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.