Stent-assisted coiling using the pEGASUS-HPC stent for acutely ruptured wide-necked intracranial aneurysms: A multicenter retrospective study

BackgroundStent-assisted coiling (SAC) is increasingly used to treat ruptured wide-necked intracranial aneurysms. The pEGASUS-HPC stent, featuring a hydrophilic polymer coating (HPC) to reduce thrombogenicity, may offer a safe option in subarachnoid hemorrhage (SAH). This study evaluates its safety and efficacy in a multicenter retrospective cohort.MethodsBetween July 2021 and June 2024, 22 patients with ruptured wide-necked aneurysms were treated with pEGASUS-HPC SAC at four neurovascular centers. Procedural success, aneurysm occlusion (Modified Raymond-Roy Classification, MRRC), and clinical outcomes based on the modified Rankin Scale (mRS) at discharge and follow-up were assessed. Complications and mortality were analyzed in relation to clinical and procedural factors.ResultsStent implantation and coil embolization were successfully performed in all patients. Immediate complete occlusion (MRRC I) was achieved in 19 cases (86.4%) and reached 100% at the 3-month follow-up. The median mRS improved from 3 (2-5) at discharge to 0 (0-2) at 3 months and 0 (0-1) at final follow-up, indicating sustained recovery. In 27.3% of cases, Y-stenting was required, reflecting bifurcation complexity. One patient (4.6%) had transient in-stent thrombosis, which resolved with tirofiban. All complications were minor and managed conservatively. No retreatment was required. All three deaths (13.6%) occurred in patients with Hunt and Hess grade V and basilar artery aneurysms.ConclusionThe pEGASUS-HPC stent showed a favorable safety profile with high occlusion and recovery rates in ruptured wide-necked aneurysms. These findings support the use of surface-modified stents in the acute setting and highlight the need for prospective studies to confirm long-term safety and efficacy.

Authors

Institutions

Publication Details

Journal
Interventional Neuroradiology
Published
2025-07-13
DOI
https://doi.org/10.1177/15910199251357993
Citations
3
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
4.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stent-assisted coiling using the pEGASUS-HPC stent for acutely ruptured wide-necked intracranial aneurysms: A multicenter retrospective study

Stephan Felber, Ali Khanafer, André Kemmling, Alexander Grote et al.
3 citations
Interventional Neuroradiology
Intracranial Aneurysms: Treatment and Complications
4.17
article

Stent-assisted coiling using the pEGASUS-HPC stent for acutely ruptured wide-necked intracranial aneurysms: A multicenter retrospective study

Stephan Felber, Ali Khanafer, André Kemmling, Alexander Grote, Zarina S. Ali, Tawfik Moher Alsady, Hans H. Henkes, Christopher Nimsky, Abdallah Aburub, Oussama Dob, Mohammad Almohammad, Bayan Alhaj Mouatafa, Julia Korthäuer
article en
3 citations

Abstract

BackgroundStent-assisted coiling (SAC) is increasingly used to treat ruptured wide-necked intracranial aneurysms. The pEGASUS-HPC stent, featuring a hydrophilic polymer coating (HPC) to reduce thrombogenicity, may offer a safe option in subarachnoid hemorrhage (SAH). This study evaluates its safety and efficacy in a multicenter retrospective cohort.MethodsBetween July 2021 and June 2024, 22 patients with ruptured wide-necked aneurysms were treated with pEGASUS-HPC SAC at four neurovascular centers. Procedural success, aneurysm occlusion (Modified Raymond-Roy Classification, MRRC), and clinical outcomes based on the modified Rankin Scale (mRS) at discharge and follow-up were assessed. Complications and mortality were analyzed in relation to clinical and procedural factors.ResultsStent implantation and coil embolization were successfully performed in all patients. Immediate complete occlusion (MRRC I) was achieved in 19 cases (86.4%) and reached 100% at the 3-month follow-up. The median mRS improved from 3 (2-5) at discharge to 0 (0-2) at 3 months and 0 (0-1) at final follow-up, indicating sustained recovery. In 27.3% of cases, Y-stenting was required, reflecting bifurcation complexity. One patient (4.6%) had transient in-stent thrombosis, which resolved with tirofiban. All complications were minor and managed conservatively. No retreatment was required. All three deaths (13.6%) occurred in patients with Hunt and Hess grade V and basilar artery aneurysms.ConclusionThe pEGASUS-HPC stent showed a favorable safety profile with high occlusion and recovery rates in ruptured wide-necked aneurysms. These findings support the use of surface-modified stents in the acute setting and highlight the need for prospective studies to confirm long-term safety and efficacy.

Interventional Neuroradiology
Rhön-Klinikum (DE), Philipps University of Marburg (DE), Katharinenhospital (DE), Sana Klinikum Offenbach (DE), Gemeinschaftsklinikum Mittelrhein (DE), Klinikum Stuttgart (DE)
Good health and well-being
Openalex Percentile: Top 6%
Intracranial Aneurysms: Treatment and Complications
4.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.