Cerium oxalate precipitation: effect of process and operating parameters on cerium oxalate particle size distribution

Abstract The oxalate precipitation process has been adopted for the reconversion of plutonium nitrate present in nitric acid solution to plutonium oxide powder at the backend of nuclear fuel cycle. Due to the radioactivity associated with plutonium, the testing and development of plutonium oxalate precipitator can be conveniently performed using a non-radioactive surrogate such as cerium. In the present work, the effect of various operating and process parameters such as the concentration of nitric acid, cerium nitrate and oxalic acid, impeller design and speed, mode of precipitation on the particle size distribution of cerium oxalate was investigated. The results showed that the concentration of nitric acid and mode of precipitation were found to affect the particle size distribution of cerium oxalate to a significant extent. The D 50 of the cerium oxalate particles increased nearly five times (21–98 µm) with increasing the nitric acid concentration from 0.5 to 4.0 M. Forward strike mode of precipitation doubled the D 50 of cerium oxalate from 34 to 74 µm as compared to the typical batch precipitation. The cerium ion concentration in feed solution showed the negligible effect on D 50 of cerium oxalate, whereas width of the particle size distribution increased from 0.9 to 2.0 with increase of cerium in nitric acid from 3 to 43 g L −1 . Lowering the concentration of oxalic acid produced smaller sized particles with broad particle size distribution. For real applications, the surrogate studies showed that it is important to control the concentration of nitric acid in the feed solution for producing bigger plutonium oxalate particles, which is required for facile operation, and to minimize the loss of residual plutonium in the filtrate.

Authors

Institutions

Publication Details

Journal
Radiochimica Acta
Published
2025-07-14
DOI
https://doi.org/10.1515/ract-2025-0016
Citations
1
Primary Topic
Radioactive element chemistry and processing
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cerium oxalate precipitation: effect of process and operating parameters on cerium oxalate particle size distribution

Saroj K. Panda, P. Vishnu Anand, D. Narasimhan, Amit Kumar et al.
1 citations
Radiochimica Acta
Radioactive element chemistry and processing
0.54
article

Cerium oxalate precipitation: effect of process and operating parameters on cerium oxalate particle size distribution

Saroj K. Panda, P. Vishnu Anand, D. Narasimhan, Amit Kumar, J. Gnanasoundari, Ashwin W. Patwardhan, K. A. Venkatesan, R. Rajeev, Satyabrata Mishra, Pankaj
article en
1 citations

Abstract

Abstract The oxalate precipitation process has been adopted for the reconversion of plutonium nitrate present in nitric acid solution to plutonium oxide powder at the backend of nuclear fuel cycle. Due to the radioactivity associated with plutonium, the testing and development of plutonium oxalate precipitator can be conveniently performed using a non-radioactive surrogate such as cerium. In the present work, the effect of various operating and process parameters such as the concentration of nitric acid, cerium nitrate and oxalic acid, impeller design and speed, mode of precipitation on the particle size distribution of cerium oxalate was investigated. The results showed that the concentration of nitric acid and mode of precipitation were found to affect the particle size distribution of cerium oxalate to a significant extent. The D 50 of the cerium oxalate particles increased nearly five times (21–98 µm) with increasing the nitric acid concentration from 0.5 to 4.0 M. Forward strike mode of precipitation doubled the D 50 of cerium oxalate from 34 to 74 µm as compared to the typical batch precipitation. The cerium ion concentration in feed solution showed the negligible effect on D 50 of cerium oxalate, whereas width of the particle size distribution increased from 0.9 to 2.0 with increase of cerium in nitric acid from 3 to 43 g L −1 . Lowering the concentration of oxalic acid produced smaller sized particles with broad particle size distribution. For real applications, the surrogate studies showed that it is important to control the concentration of nitric acid in the feed solution for producing bigger plutonium oxalate particles, which is required for facile operation, and to minimize the loss of residual plutonium in the filtrate.

Radiochimica ActaVol. 113(11)
Institute of Chemical Technology (IN), Homi Bhabha National Institute (IN), Indira Gandhi Centre for Atomic Research (IN), ASA College (US), Sri Sivasubramaniya Nadar College of Engineering (IN)
Openalex Percentile: Top 34%
Radioactive element chemistry and processing
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.