Robust Preprocessing of Impulsive Motion Artifacts Using Low-Rank Matrix Recovery for Electrical Impedance Tomography

Electrical impedance tomography (EIT) is a valuable bedside tool in critical care medicine and pneumology. However, artifacts associated with body and electrode movements, especially impulsive motion artifacts, hinder its routine use in clinical scenarios. Most of the existing algorithms for EIT data preprocessing or imaging cannot effectively address this issue. In this paper, we propose a novel method, namely, robust preprocessing for EIT (RP4EIT), to preprocess EIT boundary voltages using the concept of low-rank matrix recovery. It aims to resist impulsive motion artifacts and further to enhance the imaging quality. To attain good performance on both the normal measurements and contaminated data, we design a two-stage denoising algorithm using robust statistical analysis and low-rank recovery. Specifically, EIT boundary voltages are first formulated as a matrix, where the rows and columns correspond to the channels and frames, respectively. Then, the entries corrupted by impulsive noise of the matrix are identified and considered as missing elements. Subsequently, RP4EIT exploits the low-rank property to restore the missing components. In doing so, the impulsive motion artifacts are eliminated from EIT measurements. Furthermore, the convergence guarantee of RP4EIT is established. Experimental results on phantom and patient data demonstrate that RP4EIT is able to remove the impulsive motion artifacts from boundary voltages and the recovered data yield high-quality EIT images.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Computational Imaging
Published
2025-01-01
DOI
https://doi.org/10.1109/tci.2025.3587458
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Preprocessing of Impulsive Motion Artifacts Using Low-Rank Matrix Recovery for Electrical Impedance Tomography

Meng Dai, Zhanqi Zhao, Lin Yang, Inéz Frerichs et al.
1 citations
IEEE Transactions on Computational Imaging
Electrical and Bioimpedance Tomography
0.73
article

Robust Preprocessing of Impulsive Motion Artifacts Using Low-Rank Matrix Recovery for Electrical Impedance Tomography

Meng Dai, Zhanqi Zhao, Lin Yang, Inéz Frerichs, Zhang-Lei Shi, Hing Cheung So, Xiao Peng Li
article en
1 citations

Abstract

Electrical impedance tomography (EIT) is a valuable bedside tool in critical care medicine and pneumology. However, artifacts associated with body and electrode movements, especially impulsive motion artifacts, hinder its routine use in clinical scenarios. Most of the existing algorithms for EIT data preprocessing or imaging cannot effectively address this issue. In this paper, we propose a novel method, namely, robust preprocessing for EIT (RP4EIT), to preprocess EIT boundary voltages using the concept of low-rank matrix recovery. It aims to resist impulsive motion artifacts and further to enhance the imaging quality. To attain good performance on both the normal measurements and contaminated data, we design a two-stage denoising algorithm using robust statistical analysis and low-rank recovery. Specifically, EIT boundary voltages are first formulated as a matrix, where the rows and columns correspond to the channels and frames, respectively. Then, the entries corrupted by impulsive noise of the matrix are identified and considered as missing elements. Subsequently, RP4EIT exploits the low-rank property to restore the missing components. In doing so, the impulsive motion artifacts are eliminated from EIT measurements. Furthermore, the convergence guarantee of RP4EIT is established. Experimental results on phantom and patient data demonstrate that RP4EIT is able to remove the impulsive motion artifacts from boundary voltages and the recovered data yield high-quality EIT images.

IEEE Transactions on Computational ImagingVol. 11
City University of Hong Kong (HK), Shenzhen University (CN), University Hospital Schleswig-Holstein (DE), Xijing Hospital (CN), China University of Petroleum, East China (CN), Guangzhou Medical University (CN), University of Lübeck (DE), Air Force Medical University (CN)
Affordable and clean energy
Openalex Percentile: Top 26%
Electrical and Bioimpedance Tomography
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.