Stereopsis und Wahrnehmung räumlicher Tiefe beim natürlichen Sehen

Purpose: To investigate spatial vision under natural viewing conditions a new test is introduced, and it’s results are compared to stereoacuity measured by conventional stereopsis tests. Material and Methods: The new test shows ten equal bottles at varying viewing distances of which subjects are required to name their sequence in a short period of time. The test was applied to 47 subjects with good eye health but varying stereoacuity. Both the test duration and the number of mistakes made were determined in one sequence where head movments were not allowed and in a second sequence where head movements were allowed. Stereoacuity was deteremined as the median of three repeated measurements using a conventional stereopsis test. A Spearman rang correlation test was used to determine the correlation between test duration using the bottle test and stereoacuity as well as the number of mistakes using the bottle test and stereoacuity. To make assumptions for subjects with reproducible values for stereopsis only, the statistical analysis was repeated after removal of eight subjects from the sample whose stereoacuity exceeded 300arcsec. Results: Statistical analysis shows a positive correlation between test duration for the bottle test and stereoacuity (r = 0,33; p = 0,02) as well as the number of mistakes for the bottle test and stereoacuity (r = 0,45; p = 0,001). Furthermore, it shows significant differences in both test duration (p = 0,02) and the number of mistakes (p = 0,04) when subjects with stereoacuity ≤ 100 arcsec and > 100 arcsec are compared. If all subjects with stereoacuity > 300 arcsec are excluded from the sample no significant differences were found between subjects with stereoacuity ≤ 100 arcsec and > 100 arcsec. In addition, the results show that head movements improve the performance for the bottle test. Conclusion: The bottle test introduced in this study is suitable to asses spatial vision under natural viewing conditions. Subjects with good stereoacuity perform better than subjects with low stereoacuity. Performance deteriorates significantly if stereoacuity exceeds 300 arcsec. Hence, it is recommended to consider an increase of the commonly used stereoacuity threshold of 100 arcsec up to 300 arcsec.

Authors

Publication Details

Journal
Optometry & contact lenses
Published
2025-06-27
DOI
https://doi.org/10.54352/dozv.cspu5685
Primary Topic
Visual perception and processing mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stereopsis und Wahrnehmung räumlicher Tiefe beim natürlichen Sehen

Loreen Roth, Ralph Krüger, Holger Dietze
Optometry & contact lenses
Visual perception and processing mechanisms
article

Stereopsis und Wahrnehmung räumlicher Tiefe beim natürlichen Sehen

Loreen Roth, Ralph Krüger, Holger Dietze
article en

Abstract

Purpose: To investigate spatial vision under natural viewing conditions a new test is introduced, and it’s results are compared to stereoacuity measured by conventional stereopsis tests. Material and Methods: The new test shows ten equal bottles at varying viewing distances of which subjects are required to name their sequence in a short period of time. The test was applied to 47 subjects with good eye health but varying stereoacuity. Both the test duration and the number of mistakes made were determined in one sequence where head movments were not allowed and in a second sequence where head movements were allowed. Stereoacuity was deteremined as the median of three repeated measurements using a conventional stereopsis test. A Spearman rang correlation test was used to determine the correlation between test duration using the bottle test and stereoacuity as well as the number of mistakes using the bottle test and stereoacuity. To make assumptions for subjects with reproducible values for stereopsis only, the statistical analysis was repeated after removal of eight subjects from the sample whose stereoacuity exceeded 300arcsec. Results: Statistical analysis shows a positive correlation between test duration for the bottle test and stereoacuity (r = 0,33; p = 0,02) as well as the number of mistakes for the bottle test and stereoacuity (r = 0,45; p = 0,001). Furthermore, it shows significant differences in both test duration (p = 0,02) and the number of mistakes (p = 0,04) when subjects with stereoacuity ≤ 100 arcsec and > 100 arcsec are compared. If all subjects with stereoacuity > 300 arcsec are excluded from the sample no significant differences were found between subjects with stereoacuity ≤ 100 arcsec and > 100 arcsec. In addition, the results show that head movements improve the performance for the bottle test. Conclusion: The bottle test introduced in this study is suitable to asses spatial vision under natural viewing conditions. Subjects with good stereoacuity perform better than subjects with low stereoacuity. Performance deteriorates significantly if stereoacuity exceeds 300 arcsec. Hence, it is recommended to consider an increase of the commonly used stereoacuity threshold of 100 arcsec up to 300 arcsec.

Optometry & contact lensesVol. 5(6)
Openalex Percentile: Top 84%
Visual perception and processing mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.