Determining factors affecting the accuracy of SEM-EDX data-based quantitative chemical analysis for identifying naturally occurring individual carcinogenic erionite fibers

Erionite is a fibrous zeolite classified as a Group 1 carcinogen and may pose a significant public health hazard when aerosolized into individual respirable-sized fibers. SEM-EDXA has been widely used to identify individual erionite fibers in environmental samples as it combines morphological imaging with elemental analysis. However, the reliability of SEM-EDXA data when applied to the quantitative chemical analysis of individual erionite fibers rather than bulk samples remains uncertain. This study analyzed 325 individual erionite fibers (obtained from a bulk sample with high-purity) across a range of fiber widths and four commonly used sample preparation methods, using two different SEM-EDS systems. SEM-EDXA results were compared with previously acquired EPMA reference data from the bulk sample to assess analytical accuracy. Systematic overestimations of Si and Mg and underestimations of Al, K, and Ca were observed. Framework elements (Si and Al) exhibited relatively stable detection in fibers > 0.5 μm. However, preparation methods-deionized water dispersion and hydrogen peroxide digestion-introduced greater variability, likely due to ion exchange and cation mobilization. Despite the purity of the erionite bulk sample, none of the analyzed individual fibers fully met the established quantitative chemical criteria for erionite identification. These results highlight the need for pre-calibration with erionite standards and the application of correction index to improve SEM-EDX accuracy, and subsequent confirmation of mineralogy using TEM-SAED, when determining whether individual fibers found in airborne samples are erionite.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-13
DOI
https://doi.org/10.1038/s41598-025-09551-5
Citations
4
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
6.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining factors affecting the accuracy of SEM-EDX data-based quantitative chemical analysis for identifying naturally occurring individual carcinogenic erionite fibers

Jennifer Salmond, Alessandro Francesco Gualtieri, Janki Patel, Ayrton Hamilton et al.
4 citations
Scientific Reports
Radioactivity and Radon Measurements
6.16
article

Determining factors affecting the accuracy of SEM-EDX data-based quantitative chemical analysis for identifying naturally occurring individual carcinogenic erionite fibers

Jennifer Salmond, Alessandro Francesco Gualtieri, Janki Patel, Ayrton Hamilton, Wenxia Fan
article en
4 citations

Abstract

Erionite is a fibrous zeolite classified as a Group 1 carcinogen and may pose a significant public health hazard when aerosolized into individual respirable-sized fibers. SEM-EDXA has been widely used to identify individual erionite fibers in environmental samples as it combines morphological imaging with elemental analysis. However, the reliability of SEM-EDXA data when applied to the quantitative chemical analysis of individual erionite fibers rather than bulk samples remains uncertain. This study analyzed 325 individual erionite fibers (obtained from a bulk sample with high-purity) across a range of fiber widths and four commonly used sample preparation methods, using two different SEM-EDS systems. SEM-EDXA results were compared with previously acquired EPMA reference data from the bulk sample to assess analytical accuracy. Systematic overestimations of Si and Mg and underestimations of Al, K, and Ca were observed. Framework elements (Si and Al) exhibited relatively stable detection in fibers > 0.5 μm. However, preparation methods-deionized water dispersion and hydrogen peroxide digestion-introduced greater variability, likely due to ion exchange and cation mobilization. Despite the purity of the erionite bulk sample, none of the analyzed individual fibers fully met the established quantitative chemical criteria for erionite identification. These results highlight the need for pre-calibration with erionite standards and the application of correction index to improve SEM-EDX accuracy, and subsequent confirmation of mineralogy using TEM-SAED, when determining whether individual fibers found in airborne samples are erionite.

Scientific ReportsVol. 15(1)
University of Modena and Reggio Emilia (IT), University of Auckland (NZ)
Zero hunger
Openalex Percentile: Top 4%
Radioactivity and Radon Measurements
6.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.