KAJIAN MODIFIKASI BOTTOM OUTLET BENDUNGAN BUDONG-BUDONG KABUPATEN MAMUJU TENGAH, SULAWESI BARAT

This study evaluates the outlet system design for the Budong-Budong Dam, with a focus on optimizing downstream water delivery for irrigation purposes, calculated at 410 liters per second. The outlet structures are categorized by their discharge pathways: river outlet channels, channel outlet channels, and pressurized pipe outlets. A bottom outlet is proposed to aid in meeting irrigation demands, with hydraulic analysis conducted to determine the optimal diameter for efficient water flow. Two diameters (0.4 m and 0.6 m) were analyzed for total head loss, factoring in head loss from the trash rack, entrance, and friction. Results show that a 0.4 m diameter produces a head loss of 4.2905 m, while a 0.6 m diameter produces a head loss of 1.8599 m, consistent with Bernoulli’s Principle that smaller cross-sectional areas increase head loss. Both diameters meet the required downstream discharge of 0.705 m³/s, with head loss remaining within safety limits across hollow jet valve openings. The study concludes that both diameters are feasible for downstream discharge requirements, with the installation of the bottom outlet coordinated in parallel with diversion tunnel excavation for project efficiency.

Authors

Publication Details

Journal
Racic Rab Construction Research
Published
2025-06-29
DOI
https://doi.org/10.36341/racic.v10i1.5347
Primary Topic
Economic Growth and Fiscal Policies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

KAJIAN MODIFIKASI BOTTOM OUTLET BENDUNGAN BUDONG-BUDONG KABUPATEN MAMUJU TENGAH, SULAWESI BARAT

Albi Daniel Hasudungan, Kresno Wikan Sadono
Racic Rab Construction Research
Economic Growth and Fiscal Policies
article

KAJIAN MODIFIKASI BOTTOM OUTLET BENDUNGAN BUDONG-BUDONG KABUPATEN MAMUJU TENGAH, SULAWESI BARAT

Albi Daniel Hasudungan, Kresno Wikan Sadono
article en

Abstract

This study evaluates the outlet system design for the Budong-Budong Dam, with a focus on optimizing downstream water delivery for irrigation purposes, calculated at 410 liters per second. The outlet structures are categorized by their discharge pathways: river outlet channels, channel outlet channels, and pressurized pipe outlets. A bottom outlet is proposed to aid in meeting irrigation demands, with hydraulic analysis conducted to determine the optimal diameter for efficient water flow. Two diameters (0.4 m and 0.6 m) were analyzed for total head loss, factoring in head loss from the trash rack, entrance, and friction. Results show that a 0.4 m diameter produces a head loss of 4.2905 m, while a 0.6 m diameter produces a head loss of 1.8599 m, consistent with Bernoulli’s Principle that smaller cross-sectional areas increase head loss. Both diameters meet the required downstream discharge of 0.705 m³/s, with head loss remaining within safety limits across hollow jet valve openings. The study concludes that both diameters are feasible for downstream discharge requirements, with the installation of the bottom outlet coordinated in parallel with diversion tunnel excavation for project efficiency.

Racic Rab Construction ResearchVol. 10(1)
Openalex Percentile: Top 76%
Economic Growth and Fiscal Policies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

KAJIAN MODIFIKASI BOTTOM OUTLET BENDUNGAN BUDONG-BUDONG KABUPATEN MAMUJU TENGAH, SULAWESI BARAT — Albi Daniel Hasudungan, Kresno Wikan Sadono · Racic Rab Construction Research (2025) | TGRS Research Map | TGRS