Comparison of Experimental and Simulation Results of Cooling Performance by Using Heat Pipe Combined With Forced Air Cooling for Lithium‐Ion Batteries

ABSTRACT In this work, the battery thermal management system (BTMS) using heat pipe and forced air cooling for NMC lithium‐ion batteries was designed. The effect of air velocity on cooling performance was studied and compared between experimental and simulation results. All studies were conducted on lithium nickel manganese cobalt oxide (NMC) pouch cells with a 20 Ah capacity in seven series connections, under air velocities of 6.3, 9.5, and 12.7 m/s, with 4C discharge rates, at room temperature 22°C. The cooling performance was considered from two variables: the maximum temperature of the battery in the pack ( T max ) and the maximum temperature difference of the battery in the pack (▵ T max ). Both the experimental and simulation results indicated that increasing the air velocity has the effect of decreasing the T max , while the ▵ T max did not differ significantly. The appropriated air velocity was 9.5 m/s. The behaviour from the simulation method was consistent with the experimental method, but the magnitude of the temperature fluctuations was still very large. At an air velocity of 9.5 m/s, T max from simulation was only 33.1°C, while the experimental result was 44.3°C. The ▵ T max from the simulation was only 1.9°C, while the experimental result was 11.1°C. The main reason for the large difference was the properties of the materials used in the experiments, including batteries and heat pipes.

Authors

Institutions

Publication Details

Journal
IET Energy Systems Integration
Published
2025-01-01
DOI
https://doi.org/10.1049/esi2.70013
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Experimental and Simulation Results of Cooling Performance by Using Heat Pipe Combined With Forced Air Cooling for Lithium‐Ion Batteries

Teerawat Klabklay, Chaiyut Sumpavakup, Chokchai Anamtawach
IET Energy Systems Integration
Advanced Battery Technologies Research
article

Comparison of Experimental and Simulation Results of Cooling Performance by Using Heat Pipe Combined With Forced Air Cooling for Lithium‐Ion Batteries

Teerawat Klabklay, Chaiyut Sumpavakup, Chokchai Anamtawach
article en

Abstract

ABSTRACT In this work, the battery thermal management system (BTMS) using heat pipe and forced air cooling for NMC lithium‐ion batteries was designed. The effect of air velocity on cooling performance was studied and compared between experimental and simulation results. All studies were conducted on lithium nickel manganese cobalt oxide (NMC) pouch cells with a 20 Ah capacity in seven series connections, under air velocities of 6.3, 9.5, and 12.7 m/s, with 4C discharge rates, at room temperature 22°C. The cooling performance was considered from two variables: the maximum temperature of the battery in the pack ( T max ) and the maximum temperature difference of the battery in the pack (▵ T max ). Both the experimental and simulation results indicated that increasing the air velocity has the effect of decreasing the T max , while the ▵ T max did not differ significantly. The appropriated air velocity was 9.5 m/s. The behaviour from the simulation method was consistent with the experimental method, but the magnitude of the temperature fluctuations was still very large. At an air velocity of 9.5 m/s, T max from simulation was only 33.1°C, while the experimental result was 44.3°C. The ▵ T max from the simulation was only 1.9°C, while the experimental result was 11.1°C. The main reason for the large difference was the properties of the materials used in the experiments, including batteries and heat pipes.

IET Energy Systems IntegrationVol. 7(1)
King Mongkut's University of Technology North Bangkok (TH)
National Research Council of Thailand, King Mongkut's University of Technology North Bangkok
Openalex Percentile: Top 83%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Experimental and Simulation Results of Cooling Performance by Using Heat Pipe Combined With Forced Air Cooling for Lithium‐Ion Batteries — Teerawat Klabklay, Chaiyut Sumpavakup, et al. · IET Energy Systems Integration (2025) | TGRS Research Map | TGRS