Indocyanine green fluorescence imaging of the common bile duct blood supply in the prevention of biliary complications in liver transplantation: rationale and results

Objective: to enhance liver transplant (LT) outcomes by developing and implementing intraoperative fluorescence imaging of common bile duct (CBD) blood supply using indocyanine green (ICG). Material and methods. The study analyzed treatment outcomes in 203 recipients who received a whole liver from deceased donors. In the first stage, the incidence and potential risk factors of biliary complications were assessed in Group I, comprising 138 patients. The median follow-up period was 35.6 months (IQR: 25–68 months). Group II consisted of 65 cases, with a median follow-up of 7.2 months (IQR: 6.5–13). In this group, intraoperative ICG fluorescence imaging was employed to assess CBD blood supply. Following cholecystectomy, a 5 mL intravenous injection of ICG solution (2.5 mg/mL) was administered. Near-infrared fluorescence imaging was then performed by overlaying near-infrared light onto white light to visualize ICG fluorescence in CBD tissues. In cases where fluorescence imaging indicated hypoperfusion of the distal part of the graft’s CBD, the affected segment was excised within the boundaries of well-perfused tissue. In all cases, the resected CBD portions were sent for histological exami- nation. Results. In Group I, biliary anastomosis complications were recorded in 13 out of 138 cases (9.4%), all of which were strictures. Analysis of potential risk factors on both the recipient and donor sides did not reveal any statistically significant associations (p > 0.05). Comparison of intraoperative fluorescence imaging results with postoperative histological examination demonstrated a sensitivity of 87% and a specificity of 92% for detecting ischemic changes in CBD. In groups with comparable baseline characteristics (p > 0.05), the incidence of biliary anastomotic strictures (BAS) was significantly lower in the ICG imaging group: 9.4% in Group I versus 1.5% in Group II (p = 0.04). Conclusion. The use of fluorescence imaging to assess the blood supply of the CBD in LT is an effective method for preventing biliary complications. This technique enables the formation of biliary anastomosis within a well-perfused tissue, significantly reducing the risk of BAS.

Authors

Institutions

Publication Details

Journal
Russian Journal of Transplantology and Artificial Organs
Published
2025-07-12
DOI
https://doi.org/10.15825/1995-1191-2025-2-31-38
Primary Topic
Organ Transplantation Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indocyanine green fluorescence imaging of the common bile duct blood supply in the prevention of biliary complications in liver transplantation: rationale and results

Z. A. Bagateliya, E. A. Lidzhievа, Pavel A. Drozdov, А. В. Шабунин et al.
Russian Journal of Transplantology and Artificial Organs
Organ Transplantation Techniques and Outcomes
article

Indocyanine green fluorescence imaging of the common bile duct blood supply in the prevention of biliary complications in liver transplantation: rationale and results

Z. A. Bagateliya, E. A. Lidzhievа, Pavel A. Drozdov, А. В. Шабунин, S. А. Astapovich, Д. А. Макеев
article en

Abstract

Objective: to enhance liver transplant (LT) outcomes by developing and implementing intraoperative fluorescence imaging of common bile duct (CBD) blood supply using indocyanine green (ICG). Material and methods. The study analyzed treatment outcomes in 203 recipients who received a whole liver from deceased donors. In the first stage, the incidence and potential risk factors of biliary complications were assessed in Group I, comprising 138 patients. The median follow-up period was 35.6 months (IQR: 25–68 months). Group II consisted of 65 cases, with a median follow-up of 7.2 months (IQR: 6.5–13). In this group, intraoperative ICG fluorescence imaging was employed to assess CBD blood supply. Following cholecystectomy, a 5 mL intravenous injection of ICG solution (2.5 mg/mL) was administered. Near-infrared fluorescence imaging was then performed by overlaying near-infrared light onto white light to visualize ICG fluorescence in CBD tissues. In cases where fluorescence imaging indicated hypoperfusion of the distal part of the graft’s CBD, the affected segment was excised within the boundaries of well-perfused tissue. In all cases, the resected CBD portions were sent for histological exami- nation. Results. In Group I, biliary anastomosis complications were recorded in 13 out of 138 cases (9.4%), all of which were strictures. Analysis of potential risk factors on both the recipient and donor sides did not reveal any statistically significant associations (p > 0.05). Comparison of intraoperative fluorescence imaging results with postoperative histological examination demonstrated a sensitivity of 87% and a specificity of 92% for detecting ischemic changes in CBD. In groups with comparable baseline characteristics (p > 0.05), the incidence of biliary anastomotic strictures (BAS) was significantly lower in the ICG imaging group: 9.4% in Group I versus 1.5% in Group II (p = 0.04). Conclusion. The use of fluorescence imaging to assess the blood supply of the CBD in LT is an effective method for preventing biliary complications. This technique enables the formation of biliary anastomosis within a well-perfused tissue, significantly reducing the risk of BAS.

Russian Journal of Transplantology and Artificial OrgansVol. 27(2)
Russian Medical Academy of Continuous Professional Education (RU), Botkin Hospital (RU)
Openalex Percentile: Top 71%
Organ Transplantation Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.