A silicon membrane microfluidic oxygenator for use as an artificial placenta with minimal anticoagulation

Extreme prematurity carries a high burden of morbidity and mortality. The artificial placenta is an emerging therapy that has the potential to improve outcomes in these patients. However, current devices in development are limited by inadequate hemocompatibility, a major barrier to the translation of the artificial placenta into humans. Here, we present a novel microfluidic oxygenator that is comprised of a stacked array of semiconductor silicon membranes and operates with minimal anticoagulation (activated clotting time = 120-180 s). We describe the design, construction, and testing of two generations of prototypes. Our Generation 2 Device had an oxygen transfer of 1.51 ± 0.25 volume % (mean ± standard error). Computational fluid dynamics (CFD) modeling demonstrated favorable blood flow properties, including laminar flow, no stasis or recirculation, and optimal wall shear stress. In vivo testing in a 6 hour neonatal swine model showed that the silicon membrane oxygenator could operate with low-dose anticoagulation with minimal clot formation. Furthermore, the oxygenator had no significant effect on markers of animal health, including inflammation (white blood cell count), coagulation (platelet count, prothrombin time), or hemolysis (hematocrit, plasma free hemoglobin). This study represents a key advance toward developing an anticoagulation-free oxygenator and ultimately bringing artificial placenta technology to patients.

Authors

Institutions

Publication Details

Journal
Bioengineering & Translational Medicine
Published
2025-07-12
DOI
https://doi.org/10.1002/btm2.70037
Citations
1
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A silicon membrane microfluidic oxygenator for use as an artificial placenta with minimal anticoagulation

Jarrett Moyer, Nathan Wright, Benjamin W. Chui, Shuvo Roy et al.
1 citations
Bioengineering & Translational Medicine
Neonatal Respiratory Health Research
1.52
article

A silicon membrane microfluidic oxygenator for use as an artificial placenta with minimal anticoagulation

Jarrett Moyer, Nathan Wright, Benjamin W. Chui, Shuvo Roy, Charles Blaha, Francisco J. Baltazar, Bianca N. De, David G. Blauvelt, Anne Hesek, Nicholas C. Higgins, Prasad Nithianandam
article en
1 citations

Abstract

Extreme prematurity carries a high burden of morbidity and mortality. The artificial placenta is an emerging therapy that has the potential to improve outcomes in these patients. However, current devices in development are limited by inadequate hemocompatibility, a major barrier to the translation of the artificial placenta into humans. Here, we present a novel microfluidic oxygenator that is comprised of a stacked array of semiconductor silicon membranes and operates with minimal anticoagulation (activated clotting time = 120-180 s). We describe the design, construction, and testing of two generations of prototypes. Our Generation 2 Device had an oxygen transfer of 1.51 ± 0.25 volume % (mean ± standard error). Computational fluid dynamics (CFD) modeling demonstrated favorable blood flow properties, including laminar flow, no stasis or recirculation, and optimal wall shear stress. In vivo testing in a 6 hour neonatal swine model showed that the silicon membrane oxygenator could operate with low-dose anticoagulation with minimal clot formation. Furthermore, the oxygenator had no significant effect on markers of animal health, including inflammation (white blood cell count), coagulation (platelet count, prothrombin time), or hemolysis (hematocrit, plasma free hemoglobin). This study represents a key advance toward developing an anticoagulation-free oxygenator and ultimately bringing artificial placenta technology to patients.

Bioengineering & Translational MedicineVol. 10(5)
Thomas Jefferson University (US), University of California, San Francisco (US), Nemours Children's Health System (US)
U.S. Department of Defense, Thrasher Research Fund, National Institutes of Health, University of California, San Francisco
Openalex Percentile: Top 16%
Neonatal Respiratory Health Research
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.