Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

ABSTRACT Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2025-01-01
DOI
https://doi.org/10.1049/gtd2.70094
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Barry Mather, Akanksha Singh, Xiangqi Zhu
IET Generation Transmission & Distribution
HVDC Systems and Fault Protection
article

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Barry Mather, Akanksha Singh, Xiangqi Zhu
article en

Abstract

ABSTRACT Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

IET Generation Transmission & DistributionVol. 19(1)
National Laboratory of the Rockies (US), Oregon State University (US), Hanby Environmental (United States) (US)
Openalex Percentile: Top 85%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.