Magnetic Integration Applied to an Isolated Single-Stage AC–DC Converter

This work proposes a novel magnetic integration approach applied to a four-leg interleaved single-phase ac-dc converter topology, aimed at minimizing component count and increasing power density. The proposed design integrates an input filter inductor, two autotransformers, and two high-frequency transformers into a single magnetic structure. Using an equivalent electrical circuit model, a consistent methodology and an iterative optimized design process are derived. The magnetic arrangement and design methodology are experimentally validated using a 6.6 kW prototype. A comparative analysis with multi-component structures across various designsis presented based on a Pareto front, demonstrating that the proposed magnetic integration solution achieves lower magnetic losses and a reduced volume. Within a switching frequency range of 50 kHz to 200 kHz, reductions of up to 33.16% in losses and 55.89% in the magnetic volume are achieved.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1109/ojpel.2025.3588047
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Integration Applied to an Isolated Single-Stage AC–DC Converter

Samanta Gadelha Barbosa, Demercil S. Oliveira, Fernando Lessa Tofoli, Jens Friebe et al.
IEEE Open Journal of Power Electronics
Electric Motor Design and Analysis
article

Magnetic Integration Applied to an Isolated Single-Stage AC–DC Converter

Samanta Gadelha Barbosa, Demercil S. Oliveira, Fernando Lessa Tofoli, Jens Friebe, José W. M. de Araújo
article en

Abstract

This work proposes a novel magnetic integration approach applied to a four-leg interleaved single-phase ac-dc converter topology, aimed at minimizing component count and increasing power density. The proposed design integrates an input filter inductor, two autotransformers, and two high-frequency transformers into a single magnetic structure. Using an equivalent electrical circuit model, a consistent methodology and an iterative optimized design process are derived. The magnetic arrangement and design methodology are experimentally validated using a 6.6 kW prototype. A comparative analysis with multi-component structures across various designsis presented based on a Pareto front, demonstrating that the proposed magnetic integration solution achieves lower magnetic losses and a reduced volume. Within a switching frequency range of 50 kHz to 200 kHz, reductions of up to 33.16% in losses and 55.89% in the magnetic volume are achieved.

IEEE Open Journal of Power ElectronicsVol. 6
University of Kassel (DE), Universidade Federal do Ceará (BR), University for International Integration of the Afro-Brazilian Lusophony (BR)
Affordable and clean energy
Openalex Percentile: Top 85%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic Integration Applied to an Isolated Single-Stage AC–DC Converter — Samanta Gadelha Barbosa, Demercil S. Oliveira, et al. · IEEE Open Journal of Power Electronics (2025) | TGRS Research Map | TGRS