Enhancing Transient and Steady-State Performance in Grid-Connected VSCs: A Comprehensive Frequency Region Analysis of Decoupling Current Units

This paper introduces an innovative synthesis of inner loop control for grid-connected Voltage Source Converters (VSCs), comprising a Decoupling Current Unit (DCU) with a classic current tracking controller. The objective is to enhance both transient and steady-state performance by reducing the inherent coupling between the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</i>- and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i>-axis current control loops. The proposed DCU is formulated through a generalized control design approach that can be configured according to the dynamics of practical filter types, including L, LC, and LCL structures. Decoupling effectiveness is assessed through a model-independent Relative Gain Array (RGA) analysis, while the robustness of the inner control loop under parameter uncertainties is evaluated to ensure reliable steady-state performance. Theoretical analysis confirms that the proposed DCU effectively suppresses inter-axis coupling, producing RGA profiles that closely align with ideal decoupling across different filter configurations. These findings are further validated through simulation studies under both linear and nonlinear load conditions. Compared to a classic non-decoupled control scheme, the proposed method achieves substantial improvements: approximately 55% reduction in overshoot, up to 70% suppression of cross-coupling effects following power step changes, more than 60% improvement in reactive power tracking accuracy.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3588464
Citations
1
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Transient and Steady-State Performance in Grid-Connected VSCs: A Comprehensive Frequency Region Analysis of Decoupling Current Units

Mehdi Forouzanfar, Seyyed Mohammad Sadegh Ghiasi, Anna Pinnarelli, Giovanni Brusco et al.
1 citations
IEEE Access
Silicon Carbide Semiconductor Technologies
0.73
article

Enhancing Transient and Steady-State Performance in Grid-Connected VSCs: A Comprehensive Frequency Region Analysis of Decoupling Current Units

Mehdi Forouzanfar, Seyyed Mohammad Sadegh Ghiasi, Anna Pinnarelli, Giovanni Brusco, Daniele Menniti, Nicola Sorrentino, Pasquale Vizza, Hossein Safaiepour
article en
1 citations

Abstract

This paper introduces an innovative synthesis of inner loop control for grid-connected Voltage Source Converters (VSCs), comprising a Decoupling Current Unit (DCU) with a classic current tracking controller. The objective is to enhance both transient and steady-state performance by reducing the inherent coupling between the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</i>- and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i>-axis current control loops. The proposed DCU is formulated through a generalized control design approach that can be configured according to the dynamics of practical filter types, including L, LC, and LCL structures. Decoupling effectiveness is assessed through a model-independent Relative Gain Array (RGA) analysis, while the robustness of the inner control loop under parameter uncertainties is evaluated to ensure reliable steady-state performance. Theoretical analysis confirms that the proposed DCU effectively suppresses inter-axis coupling, producing RGA profiles that closely align with ideal decoupling across different filter configurations. These findings are further validated through simulation studies under both linear and nonlinear load conditions. Compared to a classic non-decoupled control scheme, the proposed method achieves substantial improvements: approximately 55% reduction in overshoot, up to 70% suppression of cross-coupling effects following power step changes, more than 60% improvement in reactive power tracking accuracy.

IEEE AccessVol. 13
University of Calabria (IT)
Ministero dello Sviluppo Economico
Climate action
Openalex Percentile: Top 26%
Silicon Carbide Semiconductor Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.