Harmonic Braking-Based Optimization Scheme for Saturation Protection of Converter Transformer

This paper proposes an optimization scheme for converter current saturation protection based on harmonic ratio braking, which solves the problem of saturation protection action caused by inrush current. Saturation protection can effectively protect the converter transformer from the influence of direct current (DC) bias, preventing local overheating or insulation damage. When the converter transformer is under DC bias or inrush current scenarios, the method by setting the ratio or the change rate of the third harmonic to the second harmonic,can block saturation protection and prevent saturation protection action caused by inrush current,it also has certain application value for improving the reliability of saturation protection action. Simulation results verify the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/cepgt64143.2024.11064759
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Braking-Based Optimization Scheme for Saturation Protection of Converter Transformer

X. Gu, Xuchao Ren, Maohui He, Yaming Ge
Power Systems Fault Detection
article

Harmonic Braking-Based Optimization Scheme for Saturation Protection of Converter Transformer

X. Gu, Xuchao Ren, Maohui He, Yaming Ge
article en

Abstract

This paper proposes an optimization scheme for converter current saturation protection based on harmonic ratio braking, which solves the problem of saturation protection action caused by inrush current. Saturation protection can effectively protect the converter transformer from the influence of direct current (DC) bias, preventing local overheating or insulation damage. When the converter transformer is under DC bias or inrush current scenarios, the method by setting the ratio or the change rate of the third harmonic to the second harmonic,can block saturation protection and prevent saturation protection action caused by inrush current,it also has certain application value for improving the reliability of saturation protection action. Simulation results verify the effectiveness of the proposed method.

Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 62%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.