Energy Saving Optimisation of Data Centre Cooling System Based on CSSA

Data centers are becoming increasingly important in today's world due to the quick advancement of information technology. Large-scale data transmission, processing, and storage result in enormous energy consumption in data centers. Inefficient cooling equipment operation is a significant contributing reason to these data centers' excessive energy consumption. This research presents a Chaotic Sparrow Search Algorithm (CSSA)-based energy-saving optimization technique for data center cooling systems. Using the cooling system of a data center in Shanghai as an example, we establish the cooling system optimization model in accordance with the limitations of the equipment operating conditions, use the lowest energy consumption of the cooling system as the objective function, and use the chilled water supply and return water temperature, water pump flow rate, etc. as the decision variables. According to the testing results, the cooling system may minimize energy consumption by 5.99 % in precooling mixing mode, 13.39 % in natural cold source mode, and 16.79 % in chiller cold source mode after using CSSA optimization. As a result, the plan this article suggests is crucial for lowering emissions and energy consumption in data centers.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/cepgt64143.2024.11064792
Citations
1
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy Saving Optimisation of Data Centre Cooling System Based on CSSA

Ruping Shao, Jing Yang, Minjie Wang
1 citations
Heat Transfer and Optimization
0.21
article

Energy Saving Optimisation of Data Centre Cooling System Based on CSSA

Ruping Shao, Jing Yang, Minjie Wang
article en
1 citations

Abstract

Data centers are becoming increasingly important in today's world due to the quick advancement of information technology. Large-scale data transmission, processing, and storage result in enormous energy consumption in data centers. Inefficient cooling equipment operation is a significant contributing reason to these data centers' excessive energy consumption. This research presents a Chaotic Sparrow Search Algorithm (CSSA)-based energy-saving optimization technique for data center cooling systems. Using the cooling system of a data center in Shanghai as an example, we establish the cooling system optimization model in accordance with the limitations of the equipment operating conditions, use the lowest energy consumption of the cooling system as the objective function, and use the chilled water supply and return water temperature, water pump flow rate, etc. as the decision variables. According to the testing results, the cooling system may minimize energy consumption by 5.99 % in precooling mixing mode, 13.39 % in natural cold source mode, and 16.79 % in chiller cold source mode after using CSSA optimization. As a result, the plan this article suggests is crucial for lowering emissions and energy consumption in data centers.

Nanjing Tech University (CN)
Affordable and clean energy
Openalex Percentile: Top 47%
Heat Transfer and Optimization
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Energy Saving Optimisation of Data Centre Cooling System Based on CSSA — Ruping Shao, Jing Yang, et al. · (2024) | TGRS Research Map | TGRS