Application of an FR4 printed circuit board for the fabrication of a simple and low cost patterned Cu disk for the determination of paraquat

An FR4 printed circuit board was used to fabricate a patterned Cu disk electrode (p-Cu). It was modified with a Nafion layer (p-Cu/Nafion) and used as a disposable (single-use) sensor for the determination of paraquat. Cyclic voltammetry and linear sweep voltammetry (LSV) were used to obtain the optimal route for paraquat determination using p-Cu/Nafion. The effects of the concentration of Nafion, the type, concentration and pH of supporting electrolyte, and the applied accumulation time and potential on LSV responses of PQ were investigated. Two linear relationships were observed between square wave voltammetry (SWV) responses and the concentration of PQ in the range of 0.5-15 and 25-100 μM, under optimal experimental conditions. The obtained limit of detection (S/N = 3) and limit of quantification (S/N = 10) were 0.29 and 1.0 μM, respectively. The effects of the presence of possible interfering compounds on the SWV responses of PQ were examined and the sensor was applied for the determination of PQ in tomato juice with satisfactory results.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00824g
Primary Topic
Paraquat toxicity studies and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of an FR4 printed circuit board for the fabrication of a simple and low cost patterned Cu disk for the determination of paraquat

Behzad Haghighi, Narjes Negahdari
Analytical Methods
Paraquat toxicity studies and treatments
article

Application of an FR4 printed circuit board for the fabrication of a simple and low cost patterned Cu disk for the determination of paraquat

Behzad Haghighi, Narjes Negahdari
article en

Abstract

An FR4 printed circuit board was used to fabricate a patterned Cu disk electrode (p-Cu). It was modified with a Nafion layer (p-Cu/Nafion) and used as a disposable (single-use) sensor for the determination of paraquat. Cyclic voltammetry and linear sweep voltammetry (LSV) were used to obtain the optimal route for paraquat determination using p-Cu/Nafion. The effects of the concentration of Nafion, the type, concentration and pH of supporting electrolyte, and the applied accumulation time and potential on LSV responses of PQ were investigated. Two linear relationships were observed between square wave voltammetry (SWV) responses and the concentration of PQ in the range of 0.5-15 and 25-100 μM, under optimal experimental conditions. The obtained limit of detection (S/N = 3) and limit of quantification (S/N = 10) were 0.29 and 1.0 μM, respectively. The effects of the presence of possible interfering compounds on the SWV responses of PQ were examined and the sensor was applied for the determination of PQ in tomato juice with satisfactory results.

Analytical MethodsVol. 17(31)
Shiraz University (IR)
Openalex Percentile: Top 71%
Paraquat toxicity studies and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.