Study of the Possibility of Using 3D Printing in Low-Background Experiments

The paper considers the possibility of using 3D printing technology to manufacture structural elements of ionizing radiation detectors. For this purpose, a housing for a scintillation detector with a volume of approximately 73 cm $${}^{3}$$ was printed. Based on this printed housing, a scintillation detector was constructed, utilizing a scintillator made from LAB with additives of PPO (2 g/L) and Bis-MSB (0.02 g/L). The volume of the detector was viewed using a PMT-97. To verify the functionality of the experimental setup, calibration measurements were conducted with a $${}^{137}$$ Cs source, and a background spectrum was collected over 16 hours in the laboratory building of the BNO INR RAS. The results obtained confirmed the feasibility of using 3D printing for the fabrication of structural components of detectors.

Authors

Institutions

Publication Details

Journal
Physics of Atomic Nuclei
Published
2025-04-01
DOI
https://doi.org/10.1134/s1063778825700450
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the Possibility of Using 3D Printing in Low-Background Experiments

Yu. M. Gavrilyuk, A. Veresnikova, V. V. Kazalov, M. M. Kochkarov
Physics of Atomic Nuclei
Particle Detector Development and Performance
article

Study of the Possibility of Using 3D Printing in Low-Background Experiments

Yu. M. Gavrilyuk, A. Veresnikova, V. V. Kazalov, M. M. Kochkarov
article en

Abstract

The paper considers the possibility of using 3D printing technology to manufacture structural elements of ionizing radiation detectors. For this purpose, a housing for a scintillation detector with a volume of approximately 73 cm $${}^{3}$$ was printed. Based on this printed housing, a scintillation detector was constructed, utilizing a scintillator made from LAB with additives of PPO (2 g/L) and Bis-MSB (0.02 g/L). The volume of the detector was viewed using a PMT-97. To verify the functionality of the experimental setup, calibration measurements were conducted with a $${}^{137}$$ Cs source, and a background spectrum was collected over 16 hours in the laboratory building of the BNO INR RAS. The results obtained confirmed the feasibility of using 3D printing for the fabrication of structural components of detectors.

Physics of Atomic NucleiVol. 88(2)
Kabardino-Balkarian State University (RU), Institute for Nuclear Research (RU), National Research Nuclear University MEPhI (RU)
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.