Transient Behavior of Grid-Forming Converters During Phase Jumps

GFM converters could misinterpret phase jumps as rms voltage or frequency variations, leading to the misbehavior in phase jump response. This paper reveals that the behavior of GFM converters during phase jumps can be classified into three typical modes of transient responses: fast recovery, slow recovery, and loss of synchronism. The operational boundary between the three phase jump modes is correlated to the relationship between the actual phase jump angle and its critical value (namely the phase displacement between the normal operating point and the unstable equilibrium point). Influencing factors of the critical angle are identified based on transient stability analysis that incorporates the impact of current limiting design as well as the couplings between active/reactive power controllers. The stability analysis provides guidelines for developing grid specifications and testing requirements of phase jump responses of GFM converters. All given analysis is experimentally verified in a GFM converter system under different phase jump scenarios.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060291
Citations
1
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Behavior of Grid-Forming Converters During Phase Jumps

Shan Jiang, Georgios Konstantinou, Ye Zhu
1 citations
High-Voltage Power Transmission Systems
0.73
article

Transient Behavior of Grid-Forming Converters During Phase Jumps

Shan Jiang, Georgios Konstantinou, Ye Zhu
article en
1 citations

Abstract

GFM converters could misinterpret phase jumps as rms voltage or frequency variations, leading to the misbehavior in phase jump response. This paper reveals that the behavior of GFM converters during phase jumps can be classified into three typical modes of transient responses: fast recovery, slow recovery, and loss of synchronism. The operational boundary between the three phase jump modes is correlated to the relationship between the actual phase jump angle and its critical value (namely the phase displacement between the normal operating point and the unstable equilibrium point). Influencing factors of the critical angle are identified based on transient stability analysis that incorporates the impact of current limiting design as well as the couplings between active/reactive power controllers. The stability analysis provides guidelines for developing grid specifications and testing requirements of phase jump responses of GFM converters. All given analysis is experimentally verified in a GFM converter system under different phase jump scenarios.

UNSW Sydney (AU)
Openalex Percentile: Top 26%
High-Voltage Power Transmission Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transient Behavior of Grid-Forming Converters During Phase Jumps — Shan Jiang, Georgios Konstantinou, et al. · (2025) | TGRS Research Map | TGRS