Harmonic Correction Method Based on Full Frequency Passive Reference Model

In weak grid environments, digital control delays degrade the stability of capacitor current feedback (CCF), thereby deteriorating the quality of grid-connected current. To enhance system robustness, this paper proposes a harmonic correction method based on a full frequency passive reference model. First, the underlying mechanisms of CCF performance degradation under inverter control delays are systematically analyzed. Then, leveraging passivity theory, a reference model with stable positive damping characteristics is constructed, and its stable components are employed to replace the unstable components in the actual system model. The proposed method effectively mitigates the impact of grid impedance variations on CCF stability. Finally, MATLAB/Simulink simulation results validate that the proposed scheme exhibits superior robustness compared with the traditional CCF method, ensuring reliable operation under challenging weak grid conditions.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060164
Primary Topic
Industrial Technology and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Correction Method Based on Full Frequency Passive Reference Model

Qinghui Du, Damin Zhang, F. Yan, Zezhong Wu
Industrial Technology and Control Systems
article

Harmonic Correction Method Based on Full Frequency Passive Reference Model

Qinghui Du, Damin Zhang, F. Yan, Zezhong Wu
article en

Abstract

In weak grid environments, digital control delays degrade the stability of capacitor current feedback (CCF), thereby deteriorating the quality of grid-connected current. To enhance system robustness, this paper proposes a harmonic correction method based on a full frequency passive reference model. First, the underlying mechanisms of CCF performance degradation under inverter control delays are systematically analyzed. Then, leveraging passivity theory, a reference model with stable positive damping characteristics is constructed, and its stable components are employed to replace the unstable components in the actual system model. The proposed method effectively mitigates the impact of grid impedance variations on CCF stability. Finally, MATLAB/Simulink simulation results validate that the proposed scheme exhibits superior robustness compared with the traditional CCF method, ensuring reliable operation under challenging weak grid conditions.

Xiamen University (CN), Xiamen University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Fujian Province
Openalex Percentile: Top 81%
Industrial Technology and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic Correction Method Based on Full Frequency Passive Reference Model — Qinghui Du, Damin Zhang, et al. · (2025) | TGRS Research Map | TGRS