Analyzing Method for Transient Active Power Difference Between Parallel Grid-Connected Gridforming Converter

For a power station consisting of parallel gridforming (GFM) converters that are connected to a point of common coupling (PCC), it is necessary to match the transient output active power of the GFM converters to reduce circulating current losses. Therefore, it is essential to establish a method to evaluate transient active power difference (TAPD) between parallel grid-connected GFM converters, which might be affected by the mismatch of line impedance (the impedance between the converter output terminals and the PCC) or steady-state operating points. In this paper, we propose an index to quantify the severity of TAPD based on the difference in transient synchronizing power coefficients and verify the coincidence between the proposed index and the TAPD under different scenarios. The results show that the proposed evaluation method effectively analyzes the potential TAPD in a GFM power station, and solutions to mitigate TAPD are proposed.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060257
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyzing Method for Transient Active Power Difference Between Parallel Grid-Connected Gridforming Converter

Xiangjun Li, Tao Yan, YaXiaEr TuErHong, Ming Li et al.
Power Systems and Renewable Energy
article

Analyzing Method for Transient Active Power Difference Between Parallel Grid-Connected Gridforming Converter

Xiangjun Li, Tao Yan, YaXiaEr TuErHong, Ming Li, Sijia Zong, Xiaoyu Liu
article en

Abstract

For a power station consisting of parallel gridforming (GFM) converters that are connected to a point of common coupling (PCC), it is necessary to match the transient output active power of the GFM converters to reduce circulating current losses. Therefore, it is essential to establish a method to evaluate transient active power difference (TAPD) between parallel grid-connected GFM converters, which might be affected by the mismatch of line impedance (the impedance between the converter output terminals and the PCC) or steady-state operating points. In this paper, we propose an index to quantify the severity of TAPD based on the difference in transient synchronizing power coefficients and verify the coincidence between the proposed index and the TAPD under different scenarios. The results show that the proposed evaluation method effectively analyzes the potential TAPD in a GFM power station, and solutions to mitigate TAPD are proposed.

Electric Power Research Institute (US), North China Electric Power University (CN), Inner Mongolia Electric Power (China) (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 83%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analyzing Method for Transient Active Power Difference Between Parallel Grid-Connected Gridforming Converter — Xiangjun Li, Tao Yan, et al. · (2025) | TGRS Research Map | TGRS