Pulse Width Modulation Strategy for Eliminating Common-Mode Voltage in T-Type Three-Level Inverters Considering Dead Time
This study focuses on the T-type three-level voltage source inverter, offering two key methods for achieving zero common-mode voltage pulse-width modulation (ZCM-PWM): the space vector approach and the carrier-based approach. To address the challenge of common-mode voltage (CMV) fluctuations induced by dead-time (DT) effects during ZCMPWM, a novel and practical DT compensation method is proposed. This method entails delaying the rising or falling edge of the drive signal by a predetermined DT, based on the polarity of the output current, and subsequently incorporating DT into the compensated drive signal. Theoretically, the proposed enhanced ZCM-PWM method effectively eliminates the adverse effects of DT on CMV while maintaining a simple and practical implementation framework.
Authors
- Qingqing He (ORCID: https://orcid.org/0000-0002-6029-8051)
- Luying Yuan
- Keliang Zhou (ORCID: https://orcid.org/0000-0001-8626-1284)
- Yahong Chen
Institutions
- Wuhan University of Technology (CN)
Publication Details
- Published
- 2025-06-22
- DOI
- https://doi.org/10.1109/pedg62294.2025.11060366
- Primary Topic
- Multilevel Inverters and Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China