An Improved Grid-Forming Control Strategy for Three-Phase Four-Wire Converter with Unbalanced Load

With the increasing diversification of microgrid load types, grid-forming (GFM) converters face growing challenges in managing unbalanced loads, which degrade system stability and power quality. This paper investigates the harmonic characteristics of the output voltage in three-phase four-wire converters to elucidate their impact on errors in sequence component separation. To address these challenges, a novel unbalance load compensation strategy is proposed, implemented in the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$d q 0$</tex> coordinate system and leveraging a dual second-order generalized integrator (D-SOGI) filter. Compared to conventional approaches, the proposed strategy significantly enhances the accuracy of positive- and negative-sequence separation, mitigating the effects of harmonic distortions and improving the balance of the three-phase output voltage after compensation. The effectiveness of the proposed strategy is validated through simulation and experimental results, demonstrating superior performance in enhancing microgrid stability and load adaptability under unbalanced conditions.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060404
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Improved Grid-Forming Control Strategy for Three-Phase Four-Wire Converter with Unbalanced Load

Cong Chen, Tianyuan Xie, Jiazhi Wang, Xin Xiang et al.
High-Voltage Power Transmission Systems
article

An Improved Grid-Forming Control Strategy for Three-Phase Four-Wire Converter with Unbalanced Load

Cong Chen, Tianyuan Xie, Jiazhi Wang, Xin Xiang, Wuhua Li, Qi Yang
article en

Abstract

With the increasing diversification of microgrid load types, grid-forming (GFM) converters face growing challenges in managing unbalanced loads, which degrade system stability and power quality. This paper investigates the harmonic characteristics of the output voltage in three-phase four-wire converters to elucidate their impact on errors in sequence component separation. To address these challenges, a novel unbalance load compensation strategy is proposed, implemented in the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$d q 0$</tex> coordinate system and leveraging a dual second-order generalized integrator (D-SOGI) filter. Compared to conventional approaches, the proposed strategy significantly enhances the accuracy of positive- and negative-sequence separation, mitigating the effects of harmonic distortions and improving the balance of the three-phase output voltage after compensation. The effectiveness of the proposed strategy is validated through simulation and experimental results, demonstrating superior performance in enhancing microgrid stability and load adaptability under unbalanced conditions.

Hangzhou Wanxiang Polytechnic (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 85%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Improved Grid-Forming Control Strategy for Three-Phase Four-Wire Converter with Unbalanced Load — Cong Chen, Tianyuan Xie, et al. · (2025) | TGRS Research Map | TGRS