Analysis of Reverse Active Power for Grid-Forming Converters During Fault Ride-Through

This paper investigates the phenomenon of reverse active power in grid-forming voltage source converters during grid voltage recovery events. The study demonstrates that this issue originates from two primary aspects: the operating point during the fault steady state and the control dynamics. The operating point analysis reveals that maintaining a certain level of active power transmission during the fault steady state is necessary to keep the operating point within the positive-power region; otherwise, the operating point may shift into the negativepower region. Furthermore, the control dynamics cause the phase angle of the modulation voltage vector to rotate clockwise, which reduces the power angle and exacerbates the power reversal issue. Theoretical findings are validated through both simulation and experimental results.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060283
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Reverse Active Power for Grid-Forming Converters During Fault Ride-Through

Xiongfei Wang, Liang Zhao, Xiaonan Gao
High-Voltage Power Transmission Systems
article

Analysis of Reverse Active Power for Grid-Forming Converters During Fault Ride-Through

Xiongfei Wang, Liang Zhao, Xiaonan Gao
article en

Abstract

This paper investigates the phenomenon of reverse active power in grid-forming voltage source converters during grid voltage recovery events. The study demonstrates that this issue originates from two primary aspects: the operating point during the fault steady state and the control dynamics. The operating point analysis reveals that maintaining a certain level of active power transmission during the fault steady state is necessary to keep the operating point within the positive-power region; otherwise, the operating point may shift into the negativepower region. Furthermore, the control dynamics cause the phase angle of the modulation voltage vector to rotate clockwise, which reduces the power angle and exacerbates the power reversal issue. Theoretical findings are validated through both simulation and experimental results.

KTH Royal Institute of Technology (SE)
Affordable and clean energy
Openalex Percentile: Top 85%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.