High-Reliability ANPC Inverter with Fault Diagnosis and Fault-Tolerant Control for Renewable Energy Systems

This paper proposes a short-circuit (SC) fault diagnosis and fault-tolerant control strategy to address the reliability issues of active neutral-point-clamped (ANPC) threelevel inverters in renewable energy systems. This study utilizes the DESAT signal from driver chips to locate the faulty switch and establishes a mapping table between DESAT signals and SC switching tubes, enabling microsecond-level rapid fault identification. A dual-mode fault-tolerant strategy is designed: the derated mode maintains symmetrical line voltage output through phase reconstruction, while the rated mode achieves fullvoltage operation. Simulation results demonstrate that the system retains three-phase symmetry and stable operation after a singleswitch SC fault.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060305
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Reliability ANPC Inverter with Fault Diagnosis and Fault-Tolerant Control for Renewable Energy Systems

Wenxi Yao, Hao Fang, Huan Yang
Multilevel Inverters and Converters
article

High-Reliability ANPC Inverter with Fault Diagnosis and Fault-Tolerant Control for Renewable Energy Systems

Wenxi Yao, Hao Fang, Huan Yang
article en

Abstract

This paper proposes a short-circuit (SC) fault diagnosis and fault-tolerant control strategy to address the reliability issues of active neutral-point-clamped (ANPC) threelevel inverters in renewable energy systems. This study utilizes the DESAT signal from driver chips to locate the faulty switch and establishes a mapping table between DESAT signals and SC switching tubes, enabling microsecond-level rapid fault identification. A dual-mode fault-tolerant strategy is designed: the derated mode maintains symmetrical line voltage output through phase reconstruction, while the rated mode achieves fullvoltage operation. Simulation results demonstrate that the system retains three-phase symmetry and stable operation after a singleswitch SC fault.

Hangzhou Wanxiang Polytechnic (CN), ZheJiang Economic and Trade Polytechnic (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 85%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.