Sensorless Voltage Control of a Three-Phase Grid-Connected Inverter Using an Estimated Synchronous Reference Frame

This paper proposes a sensorless algorithm for phase synchronization in three-phase grid-connected inverters, designed to eliminate the use of voltage sensors. Voltage sensors often raise the system cost and complexity, and are susceptible to electrical noise, which makes sensorless alternatives more attractive for building simple and reliable inverter systems. The proposed method estimates the grid voltage in a synchronous reference frame by applying a model similar to the back electromotive force (EMF) used in permanent magnet synchronous motors (PMSMs). A disturbance observer and the arctangent function are used to calculate the grid phase and frequency, and a proportional-integral (PI) controller is applied to synchronize the inverter phase with the grid. The proposed method is verified through simulation and experimental testing, and the results confirm its feasibility and performance under various conditions.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/pedg62294.2025.11060043
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensorless Voltage Control of a Three-Phase Grid-Connected Inverter Using an Estimated Synchronous Reference Frame

Hack-Jun Kim, Byeong-Gyu Kang, Chan-In Kim, Ki‐Young Choi et al.
Advanced DC-DC Converters
article

Sensorless Voltage Control of a Three-Phase Grid-Connected Inverter Using an Estimated Synchronous Reference Frame

Hack-Jun Kim, Byeong-Gyu Kang, Chan-In Kim, Ki‐Young Choi, Myeong-Hwan Kim, Kyung-Won Min
article en

Abstract

This paper proposes a sensorless algorithm for phase synchronization in three-phase grid-connected inverters, designed to eliminate the use of voltage sensors. Voltage sensors often raise the system cost and complexity, and are susceptible to electrical noise, which makes sensorless alternatives more attractive for building simple and reliable inverter systems. The proposed method estimates the grid voltage in a synchronous reference frame by applying a model similar to the back electromotive force (EMF) used in permanent magnet synchronous motors (PMSMs). A disturbance observer and the arctangent function are used to calculate the grid phase and frequency, and a proportional-integral (PI) controller is applied to synchronize the inverter phase with the grid. The proposed method is verified through simulation and experimental testing, and the results confirm its feasibility and performance under various conditions.

Hyundai Engineering (South Korea) (KR)
Affordable and clean energy
Openalex Percentile: Top 85%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensorless Voltage Control of a Three-Phase Grid-Connected Inverter Using an Estimated Synchronous Reference Frame — Hack-Jun Kim, Byeong-Gyu Kang, et al. · (2025) | TGRS Research Map | TGRS