Comfortable, continuous, and accurate blood pressure monitoring is becoming increasingly important. However, traditional blood pressure measurement methods cannot simultaneously meet both comfort and accuracy requirements and are thus not suitable. This paper combines millimeter-wave radar sensing technology and micro-pressure technology to develop a system prototype, designs a pulse wave recovery algorithm, and a pressure wave, pulse wave bimodal fusion network, ultimately achieving accurate and comfortable blood pressure measurement. The standard deviation (STD) error for Systolic Blood Pressure (SBP) is 4.36 mmHg, with a mean error (ME) of 0.27 mmHg, and for Diastolic Blood Pressure (DBP), the STD error is 3.43 mmHg, with a ME of 0.25 mmHg. These results meet the FDA's AAMI standards.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/ichih63459.2024.11064736
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

mBP: A Comfortable and Continuous Blood Pressure Monitoring Method by Fusing Millimeter Wave and Micro-Pressure Wave

Anfu Zhou, Huadóng Ma, Zixin Zheng, Bao Junjie et al.
Non-Invasive Vital Sign Monitoring
article

mBP: A Comfortable and Continuous Blood Pressure Monitoring Method by Fusing Millimeter Wave and Micro-Pressure Wave

Anfu Zhou, Huadóng Ma, Zixin Zheng, Bao Junjie, Yiwen Huang, Rui Lyu
article en

Abstract

Comfortable, continuous, and accurate blood pressure monitoring is becoming increasingly important. However, traditional blood pressure measurement methods cannot simultaneously meet both comfort and accuracy requirements and are thus not suitable. This paper combines millimeter-wave radar sensing technology and micro-pressure technology to develop a system prototype, designs a pulse wave recovery algorithm, and a pressure wave, pulse wave bimodal fusion network, ultimately achieving accurate and comfortable blood pressure measurement. The standard deviation (STD) error for Systolic Blood Pressure (SBP) is 4.36 mmHg, with a mean error (ME) of 0.27 mmHg, and for Diastolic Blood Pressure (DBP), the STD error is 3.43 mmHg, with a ME of 0.25 mmHg. These results meet the FDA's AAMI standards.

Beijing University of Posts and Telecommunications (CN)
Openalex Percentile: Top 74%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

mBP: A Comfortable and Continuous Blood Pressure Monitoring Method by Fusing Millimeter Wave and Micro-Pressure Wave — Anfu Zhou, Huadóng Ma, et al. · (2024) | TGRS Research Map | TGRS