Matrix Transformer with Integrated Leakage Inductance

Due to the rapid growth of electric aircraft, the need for high-power converters with significant weight reduction has increased. This article proposes a matrix transformer as a solution for isolated DC/DC converters $(270 \mathrm{~V} / 28 \mathrm{~V})$. The matrix transformer enable the integration of leakage inductance through a five-leg magnetic core geometry. Four legs are used for the transformer windings, while the central leg is used for the integration and control of leakage inductance. Two winding structures are analyzed and compared: a configuration with separate primary and secondary windings, and an interleaved winding structure. The structure with lowest magnetic losses and AC resistance is selected. An optimization of the magnetic core geometry is then carried out to achieve the desired leakage inductance value while minimizing losses. The final transformer is designed for an output power of around 1 kW, reaching an efficiency of around $98 \%$.

Authors

Institutions

Publication Details

Published
2025-06-11
DOI
https://doi.org/10.1109/gpecom65896.2025.11061939
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Matrix Transformer with Integrated Leakage Inductance

Fabien Sixdenier, Christian Martin, Sanae Mensouri
Induction Heating and Inverter Technology
article

Matrix Transformer with Integrated Leakage Inductance

Fabien Sixdenier, Christian Martin, Sanae Mensouri
article en

Abstract

Due to the rapid growth of electric aircraft, the need for high-power converters with significant weight reduction has increased. This article proposes a matrix transformer as a solution for isolated DC/DC converters $(270 \mathrm{~V} / 28 \mathrm{~V})$. The matrix transformer enable the integration of leakage inductance through a five-leg magnetic core geometry. Four legs are used for the transformer windings, while the central leg is used for the integration and control of leakage inductance. Two winding structures are analyzed and compared: a configuration with separate primary and secondary windings, and an interleaved winding structure. The structure with lowest magnetic losses and AC resistance is selected. An optimization of the magnetic core geometry is then carried out to achieve the desired leakage inductance value while minimizing losses. The final transformer is designed for an output power of around 1 kW, reaching an efficiency of around $98 \%$.

Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Laboratoire Ampère (FR), Institut National des Sciences Appliquées de Lyon (FR)
Affordable and clean energy
Openalex Percentile: Top 84%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.