Implementation and Validation of a Corona Effect Model in ATPDraw
This work presents the implementation and validation of a corona effect model for high-voltage conductors using ATPDraw software. The model incorporates sinusoidal and impulsive components, accounting for environmental variables such as temperature and relative humidity. The implementation leverages the Alternative Transients Program (ATP) with nonlinear resistances (Type 92) and controlled sources (TACs), enabling dynamic simulation of corona discharges. Validation was performed by comparing experimental results obtained in a high voltage laboratory under varying conditions ($21 \mathrm{kV}-26 \mathrm{kV}, 19.5^{\circ} \mathrm{C} 25^{\circ} \mathrm{C}, 32 \%-72 \%$ humidity) with simulated waveforms, analyzing key parameters such as RMS current ($I_{\text {RMS }}$) and peak current ($I_{p}$). Results demonstrate agreement within $6 \%-15 \%$ error margins under standard conditions, though discrepancies rise to 31% under precipitation due to unmodeled nonlinear effects.
Authors
- Flavio Quizhpi Palomeque
- Mikel Cuesta (ORCID: https://orcid.org/0000-0001-6419-5394)
- S. Gallardo (ORCID: https://orcid.org/0000-0002-3703-9983)
- Alexis Labanda García
Institutions
- Politecnica Salesiana University (EC)
Publication Details
- Published
- 2025-06-11
- DOI
- https://doi.org/10.1109/gpecom65896.2025.11061876
- Primary Topic
- Power Transformer Diagnostics and Insulation
- Type
- article
- Field-Weighted Citation Impact
- 0.00