Active Distribution Networks State Estimation Under Variable Generation and Load Conditions

Traditional distribution networks consist of only centralized generation sources and carry electric energy to consumers. However, today, with the widespread use of Distributed Energy Resources (DER), Energy Storage Systems (ESS), and Electric Vehicle Charging Stations (EVCS), these systems have transformed into active structures having bi-directional power flow, that is, Active Distribution Networks (ADNs). This transformation has made distribution networks more complex and increased the need for network monitoring, control, and analysis methods. In this study, an approach is presented that power flow analysis and state estimation algorithms work together to rapidly monitor and analyze ADNs under variable generation and load conditions. This approach is implemented by combining Direct Load Flow (DLF) analysis with Weighted Least Squares (WLS) based state estimation algorithm and using measurement data obtained from Micro-Phasor Measurement Units (micro-PMU). In order to simulate real-time conditions, modified IEEE 33 bus distribution system is used, and time-varying load profiles are created with Monte Carlo Simulation. Renewable Energy Sources (RES), Battery Energy Storage Systems (BESS), and EVCS are integrated into the distribution system to create a realistic ADN structure. The obtained results show that the proposed method performs state estimation with high accuracy, and the average voltage magnitude and angle errors remain at the level of $0.15 \%$ and $1.1 \%$, respectively. Also, the average execution time of power flow analysis and state estimation is 0.0012 seconds and 0.5265 seconds, respectively. As a result, the proposed approach is a suitable solution for real-time monitoring and analysis of ADNs, thanks to its high estimation accuracy and fast execution time.

Authors

Institutions

Publication Details

Published
2025-06-11
DOI
https://doi.org/10.1109/gpecom65896.2025.11061936
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Distribution Networks State Estimation Under Variable Generation and Load Conditions

Nihat Pamuk, Ali Rıfat Boynueğri, Umut Emre Uzun, Alper Kağan Candan
Optimal Power Flow Distribution
article

Active Distribution Networks State Estimation Under Variable Generation and Load Conditions

Nihat Pamuk, Ali Rıfat Boynueğri, Umut Emre Uzun, Alper Kağan Candan
article en

Abstract

Traditional distribution networks consist of only centralized generation sources and carry electric energy to consumers. However, today, with the widespread use of Distributed Energy Resources (DER), Energy Storage Systems (ESS), and Electric Vehicle Charging Stations (EVCS), these systems have transformed into active structures having bi-directional power flow, that is, Active Distribution Networks (ADNs). This transformation has made distribution networks more complex and increased the need for network monitoring, control, and analysis methods. In this study, an approach is presented that power flow analysis and state estimation algorithms work together to rapidly monitor and analyze ADNs under variable generation and load conditions. This approach is implemented by combining Direct Load Flow (DLF) analysis with Weighted Least Squares (WLS) based state estimation algorithm and using measurement data obtained from Micro-Phasor Measurement Units (micro-PMU). In order to simulate real-time conditions, modified IEEE 33 bus distribution system is used, and time-varying load profiles are created with Monte Carlo Simulation. Renewable Energy Sources (RES), Battery Energy Storage Systems (BESS), and EVCS are integrated into the distribution system to create a realistic ADN structure. The obtained results show that the proposed method performs state estimation with high accuracy, and the average voltage magnitude and angle errors remain at the level of $0.15 \%$ and $1.1 \%$, respectively. Also, the average execution time of power flow analysis and state estimation is 0.0012 seconds and 0.5265 seconds, respectively. As a result, the proposed approach is a suitable solution for real-time monitoring and analysis of ADNs, thanks to its high estimation accuracy and fast execution time.

Manisa Celal Bayar University (TR), Energy Technologies Institute (GB), Zonguldak Bülent Ecevit University (TR), Yıldız Technical University (TR)
Affordable and clean energy
Openalex Percentile: Top 85%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.