Influence of AI Decision Support on Radiologists’ Performance and Visual Search in Screening Mammography

Background Artificial intelligence (AI) decision support may improve radiologist performance during screening mammography interpretation, but its effect on radiologists' visual search behavior remains unclear. Purpose To compare radiologist performance and visual search patterns when reading screening mammograms with and without an AI decision support system. Materials and Methods In this retrospective multireader multicase study, 12 breast screening radiologists with 4-32 years of experience (median, 12 years) from 10 institutions evaluated screening mammograms acquired between September 2016 and May 2019. Assessments were conducted unaided and with a Food and Drug Administration-approved, European Commission-marked AI decision support system, which assigns a region suspicion score from 1 to 100, with 100 indicating the highest malignancy likelihood. An eye tracker monitored readers' eye movements. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity between unaided and AI-assisted reading were compared using multireader multicase analysis software. Reading times, breast fixation coverage (percentage breast covered by fixations within 2.5° visual angle radius), fixation time, and time to first fixation within the lesion region were compared using bootstrap resampling (<i>n</i> = 20 000). Results Mammography examinations (75 with breast cancer, 75 without breast cancer) from 150 women (median age, 55 years [IQR, 50-63 years]; age range, 49-72 years) were read. The mean AUC was higher with AI support versus unaided reading (unaided, 0.93 [95% CI: 0.91, 0.96]; AI-supported, 0.97 [95% CI: 0.95, 0.98]; <i>P</i> < .001). There was no evidence of a difference in mean sensitivity (81.7% [735 of 900 readings] vs 87.2% [785 of 900]; <i>P</i> = .06), specificity (89.0% [801 of 900] vs 91.1% [820 of 900]; <i>P</i> = .46), or reading time (29.4 vs 30.8 seconds; <i>P</i> = .33). Breast fixation coverage was lower with AI support (11.1% vs 9.5% of breast area; <i>P</i> = .004), while fixation time in the lesion region was higher (4.4 vs 5.4 seconds; <i>P</i> = .006). There was no evidence of a difference in time to first fixation within the lesion region (3.4 vs 3.8 seconds; <i>P</i> = .13). Conclusion Radiologists improved their breast cancer detection accuracy when reading mammography with AI support, spending more fixation time on suspicious areas and less on the rest of the breast, indicating a more efficient search. © RSNA, 2025 <i>Supplemental material is available for this article.</i> See also the editorial by Wolfe in this issue.

Authors

Institutions

Publication Details

Journal
Radiology
Published
2025-07-01
DOI
https://doi.org/10.1148/radiol.243688
Citations
10
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
6.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of AI Decision Support on Radiologists’ Performance and Visual Search in Screening Mammography

Jessie Gommers, Lucien E. M. Duijm, D. B. Naafs, Craig K. Abbey et al.
10 citations
Radiology
Artificial Intelligence in Healthcare and Education
6.54
article

Influence of AI Decision Support on Radiologists’ Performance and Visual Search in Screening Mammography

Jessie Gommers, Lucien E. M. Duijm, D. B. Naafs, Craig K. Abbey, Cornelis J. van Rooden, Sarah D. Verboom, Mireille J. M. Broeders, Ioannis Sechopoulos, Janneke B. Houwers, Miguel P. Eckstein, Katya M. Duvivier, A Fleur van Raamt
article en
10 citations

Abstract

Background Artificial intelligence (AI) decision support may improve radiologist performance during screening mammography interpretation, but its effect on radiologists' visual search behavior remains unclear. Purpose To compare radiologist performance and visual search patterns when reading screening mammograms with and without an AI decision support system. Materials and Methods In this retrospective multireader multicase study, 12 breast screening radiologists with 4-32 years of experience (median, 12 years) from 10 institutions evaluated screening mammograms acquired between September 2016 and May 2019. Assessments were conducted unaided and with a Food and Drug Administration-approved, European Commission-marked AI decision support system, which assigns a region suspicion score from 1 to 100, with 100 indicating the highest malignancy likelihood. An eye tracker monitored readers' eye movements. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity between unaided and AI-assisted reading were compared using multireader multicase analysis software. Reading times, breast fixation coverage (percentage breast covered by fixations within 2.5° visual angle radius), fixation time, and time to first fixation within the lesion region were compared using bootstrap resampling (<i>n</i> = 20 000). Results Mammography examinations (75 with breast cancer, 75 without breast cancer) from 150 women (median age, 55 years [IQR, 50-63 years]; age range, 49-72 years) were read. The mean AUC was higher with AI support versus unaided reading (unaided, 0.93 [95% CI: 0.91, 0.96]; AI-supported, 0.97 [95% CI: 0.95, 0.98]; <i>P</i> < .001). There was no evidence of a difference in mean sensitivity (81.7% [735 of 900 readings] vs 87.2% [785 of 900]; <i>P</i> = .06), specificity (89.0% [801 of 900] vs 91.1% [820 of 900]; <i>P</i> = .46), or reading time (29.4 vs 30.8 seconds; <i>P</i> = .33). Breast fixation coverage was lower with AI support (11.1% vs 9.5% of breast area; <i>P</i> = .004), while fixation time in the lesion region was higher (4.4 vs 5.4 seconds; <i>P</i> = .006). There was no evidence of a difference in time to first fixation within the lesion region (3.4 vs 3.8 seconds; <i>P</i> = .13). Conclusion Radiologists improved their breast cancer detection accuracy when reading mammography with AI support, spending more fixation time on suspicious areas and less on the rest of the breast, indicating a more efficient search. © RSNA, 2025 <i>Supplemental material is available for this article.</i> See also the editorial by Wolfe in this issue.

RadiologyVol. 316(1)
Radboud University Nijmegen (NL), University of California, Santa Barbara (US), Maastricht University Medical Centre (NL), Gelre Hospitals (NL), University Medical Center (US), Radboud University Medical Center (NL), Maastricht University (NL), Diakonessenhuis hospital (NL), Dutch Expert Centre for Screening (NL), Canisius-Wilhelmina Ziekenhuis (NL), Haga Hospital (NL), Amsterdam University Medical Centers (NL), University of Twente (NL)
Health~Holland, Nederlandse Organisatie voor Wetenschappelijk Onderzoek, KWF Kankerbestrijding
Good health and well-being
Openalex Percentile: Top 3%
Artificial Intelligence in Healthcare and Education
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.