Modelling temperature in premise plumbing systems

ABSTRACT In this work, our main objective is to introduce, calibrate and validate a temperature model that simulates temperature fluctuations due to radial and axial heat transfer in cold- and hot-water pipes within premise plumbing systems. For this purpose, a laboratory pilot containing six shower installations was used to evaluate three setups of varying pipe material, temperature and insulation. The axial convection factor was calibrated with an initial test on the cold-water system. The results show that the calibrated model was able to accurately represent temperature fluctuations in most showers for all tests in the pilot, obtaining relatively low error. These findings also imply that water temperature fluctuations caused by non-radial heat transfer in premise plumbing systems are detectable and non-negligible during periods of low or no demand. Therefore, it is recommended to monitor and model these fluctuations, when possible, especially in the vicinity of mixing valves and hot-water heaters.

Authors

Institutions

Publication Details

Journal
Journal of Hydroinformatics
Published
2025-07-01
DOI
https://doi.org/10.2166/hydro.2025.023
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modelling temperature in premise plumbing systems

K. J. Vargas, Marius Møller Rokstad, Michael B. Waak, Franz Tscheikner-Gratl
Journal of Hydroinformatics
Water Systems and Optimization
article

Modelling temperature in premise plumbing systems

K. J. Vargas, Marius Møller Rokstad, Michael B. Waak, Franz Tscheikner-Gratl
article en

Abstract

ABSTRACT In this work, our main objective is to introduce, calibrate and validate a temperature model that simulates temperature fluctuations due to radial and axial heat transfer in cold- and hot-water pipes within premise plumbing systems. For this purpose, a laboratory pilot containing six shower installations was used to evaluate three setups of varying pipe material, temperature and insulation. The axial convection factor was calibrated with an initial test on the cold-water system. The results show that the calibrated model was able to accurately represent temperature fluctuations in most showers for all tests in the pilot, obtaining relatively low error. These findings also imply that water temperature fluctuations caused by non-radial heat transfer in premise plumbing systems are detectable and non-negligible during periods of low or no demand. Therefore, it is recommended to monitor and model these fluctuations, when possible, especially in the vicinity of mixing valves and hot-water heaters.

Journal of HydroinformaticsVol. 27(7)
SINTEF (NO), Norwegian University of Science and Technology (NO), SINTEF Community
Norges Forskningsråd
Clean water and sanitation
Openalex Percentile: Top 83%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modelling temperature in premise plumbing systems — K. J. Vargas, Marius Møller Rokstad, et al. · Journal of Hydroinformatics (2025) | TGRS Research Map | TGRS