Stress Distribution in Interlocking and Blocking Screw Fixation for Distal Tibial Intramedullary Nailing: A Finite Element Analysis

<b>Background/Objectives:</b> This study evaluates the structural strength of various fixation models for distal tibial fractures using finite element analysis, comparing the biomechanical performance of different interlocking and blocking screw configurations in intramedullary nail fixation. <b>Methods</b>: Finite element models were developed for three different screw configurations: two interlocking screws (T2S), three interlocking screws (T3S), and two interlocking screws combined with two blocking screws (T2SBS2). Material properties were assigned using SAWBONES<sup>®</sup> models, reflecting established biomechanical characteristics. The models were subjected to static axial loading (800 Nm), internal rotation (3500 Nm), and external rotation stresses. The stress distribution and structural integrity of each fixation model were analyzed. <b>Results</b>: The T3S model demonstrated the lowest maximum von Mises stress values across all loading conditions. Under axial loading, the maximum VMS at the medial first screw contact was the lowest in the T3S model (65.96 MPa) compared to T2S (135.68 MPa) and T2SBS2 (150.30 MPa). Similarly, internal rotation loading resulted in the lowest stress at the medial first screw site in T3S (64.86 MPa), compared to significantly higher stresses in T2S (136.29 MPa) and T2SBS2 (158.11 MPa). The T2SBS2 configuration showed effective stress reduction at the distal interlocking screws, highlighting its potential for improved load sharing. <b>Conclusions</b>: The findings underscore the importance of the secure fixation of the initial interlocking screw in distal tibial fractures. The fixation model utilizing three interlocking screws provided the most favorable overall stress distribution, whereas the inclusion of blocking screws effectively reduced stress concentrations at distal screw sites.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-07-05
DOI
https://doi.org/10.3390/jcm14134769
Citations
1
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stress Distribution in Interlocking and Blocking Screw Fixation for Distal Tibial Intramedullary Nailing: A Finite Element Analysis

Se-Lin Jeong, Jungtae Ahn, Gu-Hee Jung
1 citations
Journal of Clinical Medicine
Bone fractures and treatments
1.35
article

Stress Distribution in Interlocking and Blocking Screw Fixation for Distal Tibial Intramedullary Nailing: A Finite Element Analysis

Se-Lin Jeong, Jungtae Ahn, Gu-Hee Jung
article en
1 citations

Abstract

<b>Background/Objectives:</b> This study evaluates the structural strength of various fixation models for distal tibial fractures using finite element analysis, comparing the biomechanical performance of different interlocking and blocking screw configurations in intramedullary nail fixation. <b>Methods</b>: Finite element models were developed for three different screw configurations: two interlocking screws (T2S), three interlocking screws (T3S), and two interlocking screws combined with two blocking screws (T2SBS2). Material properties were assigned using SAWBONES<sup>®</sup> models, reflecting established biomechanical characteristics. The models were subjected to static axial loading (800 Nm), internal rotation (3500 Nm), and external rotation stresses. The stress distribution and structural integrity of each fixation model were analyzed. <b>Results</b>: The T3S model demonstrated the lowest maximum von Mises stress values across all loading conditions. Under axial loading, the maximum VMS at the medial first screw contact was the lowest in the T3S model (65.96 MPa) compared to T2S (135.68 MPa) and T2SBS2 (150.30 MPa). Similarly, internal rotation loading resulted in the lowest stress at the medial first screw site in T3S (64.86 MPa), compared to significantly higher stresses in T2S (136.29 MPa) and T2SBS2 (158.11 MPa). The T2SBS2 configuration showed effective stress reduction at the distal interlocking screws, highlighting its potential for improved load sharing. <b>Conclusions</b>: The findings underscore the importance of the secure fixation of the initial interlocking screw in distal tibial fractures. The fixation model utilizing three interlocking screws provided the most favorable overall stress distribution, whereas the inclusion of blocking screws effectively reduced stress concentrations at distal screw sites.

Journal of Clinical MedicineVol. 14(13)
Changwon National University (KR), Gyeongsang National University (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 18%
Bone fractures and treatments
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.