Three-Dimensional Transesophageal Echocardiography Is Useful for Preventing Prosthetic-Patient Mismatch After Surgical Aortic Valve Replacement

<b>Introduction</b>: Prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) is known to be a poor prognostic factor. However, the parameters for preventing postoperative PPM in SAVR have not been established. <b>Materials and Methods</b>: Two hundred and five patients (mean age 72.5 ± 7.4 years, 129 males) who underwent SAVR were analyzed. Preoperatively, we determined the recommended prosthesis valve size from the mean aortic valve (AV) diameter derived from the AV annulus area by preoperative three-dimensional transesophageal echocardiography (3D-TEE). We investigated the association between pre- and postoperative changes in annulus diameter and the occurrence of PPM. <b>Results</b>: PPM was present in 6 patients (2.9%). Pre- and postoperative AV annulus diameter change ratio was greater in the group with PPM than in that without PPM (10.4 ± 3.6% vs. 3.0 ± 5.6%, <i>p</i> = 0.002). The use of prosthetic valve rings smaller than the recommended size was higher in the group with PPM than in that without PPM. (83.3% vs. 20.6%, <i>p</i> = 0.002). On multivariate logistic regression analysis, use of a valve smaller than the recommended size was an independent predictor of PPM (odds ratio 19.3, 95% confidence interval 2.14-174.5, <i>p</i> = 0.008). <b>Conclusions</b>: The recommended prosthetic AV size based on preoperative 3D-TEE is useful for determining the optimal prosthetic AV size to prevent PPM after SAVR.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-07-05
DOI
https://doi.org/10.3390/jcm14134762
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Dimensional Transesophageal Echocardiography Is Useful for Preventing Prosthetic-Patient Mismatch After Surgical Aortic Valve Replacement

Hiroyuki Takaoka, Noriko Suzuki-Eguchi, Yoshio Kobayashi, Shuhei Aoki et al.
Journal of Clinical Medicine
Cardiac Valve Diseases and Treatments
article

Three-Dimensional Transesophageal Echocardiography Is Useful for Preventing Prosthetic-Patient Mismatch After Surgical Aortic Valve Replacement

Hiroyuki Takaoka, Noriko Suzuki-Eguchi, Yoshio Kobayashi, Shuhei Aoki, Makiko Kinoshita, Katsuya Suzuki, Kazuyuki Matsushita, Shuichiro Takanashi, Goro Matsumiya, Yusei Nishikawa, Kazuki Yoshida, Satomi Yashima, Moe Matsumoto, Haruka Sasaki, Y. Noguchi
article en

Abstract

<b>Introduction</b>: Prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) is known to be a poor prognostic factor. However, the parameters for preventing postoperative PPM in SAVR have not been established. <b>Materials and Methods</b>: Two hundred and five patients (mean age 72.5 ± 7.4 years, 129 males) who underwent SAVR were analyzed. Preoperatively, we determined the recommended prosthesis valve size from the mean aortic valve (AV) diameter derived from the AV annulus area by preoperative three-dimensional transesophageal echocardiography (3D-TEE). We investigated the association between pre- and postoperative changes in annulus diameter and the occurrence of PPM. <b>Results</b>: PPM was present in 6 patients (2.9%). Pre- and postoperative AV annulus diameter change ratio was greater in the group with PPM than in that without PPM (10.4 ± 3.6% vs. 3.0 ± 5.6%, <i>p</i> = 0.002). The use of prosthetic valve rings smaller than the recommended size was higher in the group with PPM than in that without PPM. (83.3% vs. 20.6%, <i>p</i> = 0.002). On multivariate logistic regression analysis, use of a valve smaller than the recommended size was an independent predictor of PPM (odds ratio 19.3, 95% confidence interval 2.14-174.5, <i>p</i> = 0.008). <b>Conclusions</b>: The recommended prosthetic AV size based on preoperative 3D-TEE is useful for determining the optimal prosthetic AV size to prevent PPM after SAVR.

Journal of Clinical MedicineVol. 14(13)
Chiba University (JP), Chiba University Hospital (JP), Kawasaki Hospital (JP)
Chiba University, Japan Society for the Promotion of Science
Openalex Percentile: Top 72%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.