Polarization diagnosis and transmission distortion calibration of the Dalian coherent light source

Polarized light serves as a fundamental tool in various scientific research, particularly in the study of chiral molecules and magnetic materials. For Free-electron Laser (FEL) sources, the Elliptical Polarized Undulator (EPU) has been extensively used as a tool to generate tunable polarized FEL. The accurate adjustment of the polarization state critically depends on the precise diagnosis of the polarization state. This work presents a Vacuum Ultraviolet (VUV) polarimeter that employs a reflection polarizer to determine the polarization state of the Dalian Coherent Light Source (DCLS), a VUV-FEL facility in Dalian, China. This instrument has been precisely installed on the DCLS-FEL2 beamline to measure the EPU-generated FEL pulses. The linear polarization angle was measured with an accuracy of ±1°, and a polarization degree of 95% was achieved at 10.2 eV photon energy. Furthermore, beamline transmission matrix calibration has been conducted to ensure precision of polarization state at downstream end-stations.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-07-01
DOI
https://doi.org/10.1063/5.0276737
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polarization diagnosis and transmission distortion calibration of the Dalian coherent light source

J.J. Wang, Zequn Wang, Mingchang Wang, Jitao Sun et al.
Review of Scientific Instruments
Advanced X-ray Imaging Techniques
article

Polarization diagnosis and transmission distortion calibration of the Dalian coherent light source

J.J. Wang, Zequn Wang, Mingchang Wang, Jitao Sun, Bingbing Zhang, Jiayue Yang, Qinming Li, Weiqing Zhang, Siyuan Tan, Xinmeng Li, Zhixiang Wen, Baoning Sun, Linxian Huang
article en

Abstract

Polarized light serves as a fundamental tool in various scientific research, particularly in the study of chiral molecules and magnetic materials. For Free-electron Laser (FEL) sources, the Elliptical Polarized Undulator (EPU) has been extensively used as a tool to generate tunable polarized FEL. The accurate adjustment of the polarization state critically depends on the precise diagnosis of the polarization state. This work presents a Vacuum Ultraviolet (VUV) polarimeter that employs a reflection polarizer to determine the polarization state of the Dalian Coherent Light Source (DCLS), a VUV-FEL facility in Dalian, China. This instrument has been precisely installed on the DCLS-FEL2 beamline to measure the EPU-generated FEL pulses. The linear polarization angle was measured with an accuracy of ±1°, and a polarization degree of 95% was achieved at 10.2 eV photon energy. Furthermore, beamline transmission matrix calibration has been conducted to ensure precision of polarization state at downstream end-stations.

Review of Scientific InstrumentsVol. 96(7)
Dalian Institute of Chemical Physics (CN), Chinese Academy of Sciences (CN), Dalian University of Technology (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Shenzhen Science and Technology Innovation Program
Affordable and clean energy
Openalex Percentile: Top 77%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.