Determination of the Corrosion and Biocompatibility Properties of As-Cast TiNi Alloys

In this study, a TiNi alloy with a composition of 50 at.% of titanium and 50 at.% of nickel is investigated in terms of its corrosion and biocompatibility behavior for biomedical applications. The corrosion measurements, which include the determination of open-circuit potential and linear polarization resistance measurements, cyclic polarization measurements, and electrochemical impedance spectroscopy in 9 g L−1 NaCl, show that TiNi has satisfactory corrosion stability. According to the SEM and EDS analysis, after cyclic polarization, pitting corrosion occurred, accompanied by the dissolution of the unstable Ti2Ni inclusions. The analysis also showed that TiNi has good biocompatibility for human osteoblast-like cells, as determined by the mitochondrial activity, which was assessed using a direct contact test following ISO standard 10993-5, via scanning electron microscopy (SEM) and fluorescent microscopy.

Authors

Institutions

Publication Details

Journal
Metals
Published
2025-07-05
DOI
https://doi.org/10.3390/met15070758
Citations
1
Primary Topic
Shape Memory Alloy Transformations
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Corrosion and Biocompatibility Properties of As-Cast TiNi Alloys

Branimir Grgur, Minja Miličić Lazić, Biljana Dojčinović, Dijana Mitić et al.
1 citations
Metals
Shape Memory Alloy Transformations
0.52
article

Determination of the Corrosion and Biocompatibility Properties of As-Cast TiNi Alloys

Branimir Grgur, Minja Miličić Lazić, Biljana Dojčinović, Dijana Mitić, Marko Lazić, Aleksandra Popović
article en
1 citations

Abstract

In this study, a TiNi alloy with a composition of 50 at.% of titanium and 50 at.% of nickel is investigated in terms of its corrosion and biocompatibility behavior for biomedical applications. The corrosion measurements, which include the determination of open-circuit potential and linear polarization resistance measurements, cyclic polarization measurements, and electrochemical impedance spectroscopy in 9 g L−1 NaCl, show that TiNi has satisfactory corrosion stability. According to the SEM and EDS analysis, after cyclic polarization, pitting corrosion occurred, accompanied by the dissolution of the unstable Ti2Ni inclusions. The analysis also showed that TiNi has good biocompatibility for human osteoblast-like cells, as determined by the mitochondrial activity, which was assessed using a direct contact test following ISO standard 10993-5, via scanning electron microscopy (SEM) and fluorescent microscopy.

MetalsVol. 15(7)
University of Belgrade (RS)
Eurostars
Openalex Percentile: Top 36%
Shape Memory Alloy Transformations
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.