Emergency Load Shedding Strategy with Warning and Delay Time Based on Energy Storage

Considering the escalating usage of renewable energy and rising frequency of extreme meteorological events, the risk of emergency load shedding (ELS) in power grids due to faults is increasing. The existing ELS strategies fail to provide users with advance warnings and blackout preparation time. To address this issue, an innovative strategy called warning and delayed load shedding is proposed in this study. In this approach, when it becomes necessary to shed load for emergency control, users are immediately notified with a power outage warning. Subsequently, energy storage and other regulatory resources are employed to substitute for load shedding, thus postponing the execution of the load shedding command. This delay equips users with the ability and time to respond and prepare. To implement this strategy, the operational principles supported by energy storage and backup power are further discussed. Five performance indexes are utilized to evaluate the delayed load shedding capability. Moreover, the delayed load shedding switch function and energy storage power balance equation are constructed to determine the relationship between energy storage, backup power sources, and load shedding time. Subsequently, two optimized load shedding models supported by energy storage are established, i.e., maximum and flexible delayed models. For comparison, improvements are made to the conventional load shedding model without delay by incorporating energy storage. An IEEE 30-node network with energy storage is used to test the three load shedding models. Accordingly, the evaluation indexes are calculated and compared. The results of the performance indexes and comparative analysis validate the effectiveness of the proposed methods, indicating that by using energy storage, users can be notified with advance power outage warnings and preparation time.

Authors

Institutions

Publication Details

Journal
Protection and Control of Modern Power Systems
Published
2025-07-01
DOI
https://doi.org/10.23919/pcmp.2024.000090
Citations
3
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
1.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Emergency Load Shedding Strategy with Warning and Delay Time Based on Energy Storage

Jun Liang, Jizhong Zhu, Xiangzhen He, Dongliang Nan et al.
3 citations
Protection and Control of Modern Power Systems
Power Systems and Renewable Energy
1.60
article

Emergency Load Shedding Strategy with Warning and Delay Time Based on Energy Storage

Jun Liang, Jizhong Zhu, Xiangzhen He, Dongliang Nan, Pengfei Yu, Xiaofu Xiong
article en
3 citations

Abstract

Considering the escalating usage of renewable energy and rising frequency of extreme meteorological events, the risk of emergency load shedding (ELS) in power grids due to faults is increasing. The existing ELS strategies fail to provide users with advance warnings and blackout preparation time. To address this issue, an innovative strategy called warning and delayed load shedding is proposed in this study. In this approach, when it becomes necessary to shed load for emergency control, users are immediately notified with a power outage warning. Subsequently, energy storage and other regulatory resources are employed to substitute for load shedding, thus postponing the execution of the load shedding command. This delay equips users with the ability and time to respond and prepare. To implement this strategy, the operational principles supported by energy storage and backup power are further discussed. Five performance indexes are utilized to evaluate the delayed load shedding capability. Moreover, the delayed load shedding switch function and energy storage power balance equation are constructed to determine the relationship between energy storage, backup power sources, and load shedding time. Subsequently, two optimized load shedding models supported by energy storage are established, i.e., maximum and flexible delayed models. For comparison, improvements are made to the conventional load shedding model without delay by incorporating energy storage. An IEEE 30-node network with energy storage is used to test the three load shedding models. Accordingly, the evaluation indexes are calculated and compared. The results of the performance indexes and comparative analysis validate the effectiveness of the proposed methods, indicating that by using energy storage, users can be notified with advance power outage warnings and preparation time.

Protection and Control of Modern Power SystemsVol. 10(4)
Chongqing University (CN), State Grid Corporation of China (China) (CN), Cardiff University (GB), South China University of Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 15%
Power Systems and Renewable Energy
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.