Experimental study on the flexural behaviour of demountable steel-concrete composite beams at room temperature and under fire exposure

In a context driven by the urgent need to promote sustainability and circularity in the construction sector, the use of demountable shear connectors in steel-concrete composite beams has a potential to make a significant contribution to reducing the carbon footprint, helping in the management of waste generated in the deconstruction stage through the “Design for Disassembly” concept. To ensure the viability of these shear connectors in practice, it is essential to understand their mechanical behaviour under various loading situations. This paper presents the outcomes of an experimental campaign comprising a series of beam tests conducted under both room and elevated temperature conditions. The results of the tests showed that, during a fire - provided that suitable protection is used for the steel beam -, the shear connectors retain their mechanical contribution and composite action between the steel beam and concrete slab is still active along fire exposure, thereby enhancing the flexural capacity of the beam. The findings from this investigation ensure the structural efficiency of demountable steel-concrete composite beams under both fire and ambient conditions, along with their alignment with the circular economy principles. This study sets the ground to facilitate the practical application of demountable steel-concrete composite beams in the construction sector. • Four bending tests on demountable steel-concrete composite beams were reported. • Two types of shear connectors were studied, showing good mechanical performance. • The demountable composite beams demonstrated a suitable fire performance. • A fire protection system was devised to meet a standard fire resistance R90.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-07-01
DOI
https://doi.org/10.1016/j.engstruct.2025.120880
Citations
1
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on the flexural behaviour of demountable steel-concrete composite beams at room temperature and under fire exposure

M.L. Romero, Christoph Odenbreit, Ana Espinós, Phattarin Mora
1 citations
Engineering Structures
Fire effects on concrete materials
0.95
article

Experimental study on the flexural behaviour of demountable steel-concrete composite beams at room temperature and under fire exposure

M.L. Romero, Christoph Odenbreit, Ana Espinós, Phattarin Mora
article en
1 citations

Abstract

In a context driven by the urgent need to promote sustainability and circularity in the construction sector, the use of demountable shear connectors in steel-concrete composite beams has a potential to make a significant contribution to reducing the carbon footprint, helping in the management of waste generated in the deconstruction stage through the “Design for Disassembly” concept. To ensure the viability of these shear connectors in practice, it is essential to understand their mechanical behaviour under various loading situations. This paper presents the outcomes of an experimental campaign comprising a series of beam tests conducted under both room and elevated temperature conditions. The results of the tests showed that, during a fire - provided that suitable protection is used for the steel beam -, the shear connectors retain their mechanical contribution and composite action between the steel beam and concrete slab is still active along fire exposure, thereby enhancing the flexural capacity of the beam. The findings from this investigation ensure the structural efficiency of demountable steel-concrete composite beams under both fire and ambient conditions, along with their alignment with the circular economy principles. This study sets the ground to facilitate the practical application of demountable steel-concrete composite beams in the construction sector. • Four bending tests on demountable steel-concrete composite beams were reported. • Two types of shear connectors were studied, showing good mechanical performance. • The demountable composite beams demonstrated a suitable fire performance. • A fire protection system was devised to meet a standard fire resistance R90.

Engineering StructuresVol. 341
University of Luxembourg (LU), ArcelorMittal (Luxembourg) (LU), Universitat Politècnica de València (ES)
Sustainable cities and communities
Openalex Percentile: Top 24%
Fire effects on concrete materials
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.