Insufficiency Fractures of the Iliac Crest Following Robot-Assisted Total Hip Arthroplasty: A Report of Two Cases

The risk of insufficiency fractures at the iliac crest following pin insertion during robot-assisted total hip arthroplasty (THA) is unknown, as there have been very few reports on this complication. Here, we report two cases of insufficiency fractures of the contralateral iliac crest following robot-assisted THA using the Mako system (Stryker Orthopaedics, Mahwah, NJ, USA). Both patients underwent left THA using the anterolateral supine approach, and three threaded bone pins (4.0 mm diameter) were inserted into the right iliac crest for pelvic array fixation. In case one, all three pins achieved bicortical fixation. In case two, one pin demonstrated long transcortical fixation with the outer cortex of the ilium, another was inserted into soft tissue, and the third pin was fixed monocortically. Postoperatively, both patients were discharged without pain or radiographic evidence of fracture; however, contralateral iliac pain developed approximately four weeks postoperatively without trauma. Insufficiency fractures of the iliac crest at the pin insertion sites were confirmed by plain radiography. Bone union was observed within three to six months of conservative treatment in both cases, with T-cane ambulation and no weight-bearing restrictions. These cases suggest that both bicortical and transcortical pin fixation to the iliac crest may cause insufficiency fractures of the iliac bone. This report highlights the need for increasing awareness of insufficiency fractures associated with pin insertion in robot-assisted THA.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-07-05
DOI
https://doi.org/10.7759/cureus.87358
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insufficiency Fractures of the Iliac Crest Following Robot-Assisted Total Hip Arthroplasty: A Report of Two Cases

Ryusuke Saito, Toshifumi Watanabe, Hiroki Katagiri, Tetsuya Jinno et al.
1 links
Cureus
Orthopaedic implants and arthroplasty
article

Insufficiency Fractures of the Iliac Crest Following Robot-Assisted Total Hip Arthroplasty: A Report of Two Cases

Ryusuke Saito, Toshifumi Watanabe, Hiroki Katagiri, Tetsuya Jinno, Tetsuya Tachibana
article en

Abstract

The risk of insufficiency fractures at the iliac crest following pin insertion during robot-assisted total hip arthroplasty (THA) is unknown, as there have been very few reports on this complication. Here, we report two cases of insufficiency fractures of the contralateral iliac crest following robot-assisted THA using the Mako system (Stryker Orthopaedics, Mahwah, NJ, USA). Both patients underwent left THA using the anterolateral supine approach, and three threaded bone pins (4.0 mm diameter) were inserted into the right iliac crest for pelvic array fixation. In case one, all three pins achieved bicortical fixation. In case two, one pin demonstrated long transcortical fixation with the outer cortex of the ilium, another was inserted into soft tissue, and the third pin was fixed monocortically. Postoperatively, both patients were discharged without pain or radiographic evidence of fracture; however, contralateral iliac pain developed approximately four weeks postoperatively without trauma. Insufficiency fractures of the iliac crest at the pin insertion sites were confirmed by plain radiography. Bone union was observed within three to six months of conservative treatment in both cases, with T-cane ambulation and no weight-bearing restrictions. These cases suggest that both bicortical and transcortical pin fixation to the iliac crest may cause insufficiency fractures of the iliac bone. This report highlights the need for increasing awareness of insufficiency fractures associated with pin insertion in robot-assisted THA.

CureusVol. 17(7)
Jichi Medical University (JP), Japan Sport Council (JP), Jichi Medical University Saitama Medical Center (JP), Dokkyo Medical University (JP), Saitama Medical University (JP)
Zero hunger
Openalex Percentile: Top 72%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.