Evaluating the Influence of Ferrule Preparation on Zirconia Endocrown Efficacy in Primary Molars: A 3D Finite Element Analysis

This article assesses the effect of different ferrule preparations on the stress distribution in the primary second molar restored with zirconia crown.Four finite element models were created to simulate different ferrule heights: M1 (0 mm), M2 (1 mm), M3 (1.5 mm), and M4 (2 mm). A lower primary second molar was scanned to create a solid model, which was imported into finite element analysis software. Simulations included varying ferrule heights, material properties, and meshing. Models were subjected to 330 N occlusal loads at vertical, oblique, and lateral angles.The analysis revealed that stress within the endocrown body increased with greater ferrule height under vertical loading. Conversely, stress levels decreased with increased ferrule height under oblique and lateral loads. Under vertical load, peak stresses were recorded as follows: endocrown body (219.5 MPa for M1), cement layer (11.7 MPa for M1 and M4), remaining tooth (36 MPa for M1), cortical bone (59.7 MPa for M1), and cancellous bone (8.7 MPa for M1 and M4). Under oblique load, stress values increased as follows: cement layer (62.9 MPa for M4), remaining tooth (59 MPa for M1), and endocrown body (203 MPa for M1). Under lateral load, stress values increased as follows: endocrown body (321 MPa for M1), cement layer (100 MPa for M4), remaining tooth (94 MPa for M1), cortical bone (154 MPa for M1), and cancellous bone (15 MPa for M1).Ferrule height significantly influences stress distribution in the tooth structure and supporting bone. Higher ferrule heights enhance structural stability by reducing stress on underlying components.

Authors

Institutions

Publication Details

Journal
European Journal of Dentistry
Published
2025-07-05
DOI
https://doi.org/10.1055/s-0045-1809534
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Influence of Ferrule Preparation on Zirconia Endocrown Efficacy in Primary Molars: A 3D Finite Element Analysis

Mahmoud El-Said Ahmed Abd El-Aziz, Mohamed AboElkasem Ahmed Wakwak, Ali Bayiumy, Yasser R. Souror et al.
1 citations
European Journal of Dentistry
Dental materials and restorations
1.68
article

Evaluating the Influence of Ferrule Preparation on Zirconia Endocrown Efficacy in Primary Molars: A 3D Finite Element Analysis

Mahmoud El-Said Ahmed Abd El-Aziz, Mohamed AboElkasem Ahmed Wakwak, Ali Bayiumy, Yasser R. Souror, Salem A. Salem Al-Sammaraie, Mohammed Said AbdAllah AbuSamadah
article en
1 citations

Abstract

This article assesses the effect of different ferrule preparations on the stress distribution in the primary second molar restored with zirconia crown.Four finite element models were created to simulate different ferrule heights: M1 (0 mm), M2 (1 mm), M3 (1.5 mm), and M4 (2 mm). A lower primary second molar was scanned to create a solid model, which was imported into finite element analysis software. Simulations included varying ferrule heights, material properties, and meshing. Models were subjected to 330 N occlusal loads at vertical, oblique, and lateral angles.The analysis revealed that stress within the endocrown body increased with greater ferrule height under vertical loading. Conversely, stress levels decreased with increased ferrule height under oblique and lateral loads. Under vertical load, peak stresses were recorded as follows: endocrown body (219.5 MPa for M1), cement layer (11.7 MPa for M1 and M4), remaining tooth (36 MPa for M1), cortical bone (59.7 MPa for M1), and cancellous bone (8.7 MPa for M1 and M4). Under oblique load, stress values increased as follows: cement layer (62.9 MPa for M4), remaining tooth (59 MPa for M1), and endocrown body (203 MPa for M1). Under lateral load, stress values increased as follows: endocrown body (321 MPa for M1), cement layer (100 MPa for M4), remaining tooth (94 MPa for M1), cortical bone (154 MPa for M1), and cancellous bone (15 MPa for M1).Ferrule height significantly influences stress distribution in the tooth structure and supporting bone. Higher ferrule heights enhance structural stability by reducing stress on underlying components.

European Journal of Dentistry
Misr University for Science and Technology (EG), Al-Azhar University (EG), Assiut University (EG)
National Research Centre
Openalex Percentile: Top 18%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.