Enhancing Precision in Off‐Axis Integrated Cavity Output Spectroscopy Sensors Through Optimal White Noise Power Injection

Abstract Residual cavity mode noise is a primary limiting factor in the detection performance of off‐axis integrated cavity output spectroscopy (OA‐ICOS). The radio‐frequency white noise (WN) perturbation technique has emerged as a highly effective method for suppressing this noise. However, optimizing the WN injection power remains a critical challenge: insufficient power fails to adequately reduce cavity mode noise, while excessive power induces spectral distortion and hampers calibration, compromising measurement reliability. Here, for the first time, an optimal WN prediction model is presented that accurately simulates the suppression of cavity mode noise and spectral distortion under different injection powers. Using methane gas measurement as an example, a systematic trade‐off analysis and extensive simulations are conducted, determining the optimal WN injection power to be −33.98 dBm. At this power level, spectral distortion is kept <0.1% and cavity mode noise is suppressed by > 99%. A 10 h continuous stability test further confirms the effectiveness of this power setting: concentration drift remains <3.8 ppb, detection precision improves by 25.5%, and the response time for the minimum detectable concentration is shortened by a factor of 7.5. This work provides valuable theoretical guidance for the design of next‐generation cavity‐enhanced trace gas analyzers.

Authors

Institutions

Publication Details

Journal
Laser & Photonics Review
Published
2025-07-05
DOI
https://doi.org/10.1002/lpor.202500094
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Precision in Off‐Axis Integrated Cavity Output Spectroscopy Sensors Through Optimal White Noise Power Injection

Chanjuan Pan, Kunyang Wang, Longtai Liu, Shiqing Xu et al.
1 citations
Laser & Photonics Review
Spectroscopy and Laser Applications
0.76
article

Enhancing Precision in Off‐Axis Integrated Cavity Output Spectroscopy Sensors Through Optimal White Noise Power Injection

Chanjuan Pan, Kunyang Wang, Longtai Liu, Shiqing Xu, Shiyu Luo, Tianzhi Jiang, Wenhui Chen
article en
1 citations

Abstract

Abstract Residual cavity mode noise is a primary limiting factor in the detection performance of off‐axis integrated cavity output spectroscopy (OA‐ICOS). The radio‐frequency white noise (WN) perturbation technique has emerged as a highly effective method for suppressing this noise. However, optimizing the WN injection power remains a critical challenge: insufficient power fails to adequately reduce cavity mode noise, while excessive power induces spectral distortion and hampers calibration, compromising measurement reliability. Here, for the first time, an optimal WN prediction model is presented that accurately simulates the suppression of cavity mode noise and spectral distortion under different injection powers. Using methane gas measurement as an example, a systematic trade‐off analysis and extensive simulations are conducted, determining the optimal WN injection power to be −33.98 dBm. At this power level, spectral distortion is kept <0.1% and cavity mode noise is suppressed by > 99%. A 10 h continuous stability test further confirms the effectiveness of this power setting: concentration drift remains <3.8 ppb, detection precision improves by 25.5%, and the response time for the minimum detectable concentration is shortened by a factor of 7.5. This work provides valuable theoretical guidance for the design of next‐generation cavity‐enhanced trace gas analyzers.

Laser & Photonics ReviewVol. 19(22)
Zhejiang University of Water Resource and Electric Power (CN), China Jiliang University (CN)
Openalex Percentile: Top 29%
Spectroscopy and Laser Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Precision in Off‐Axis Integrated Cavity Output Spectroscopy Sensors Through Optimal White Noise Power Injection — Chanjuan Pan, Kunyang Wang, et al. · Laser & Photonics Review (2025) | TGRS Research Map | TGRS