A dosimetric study to evaluate the inverse planning simulated annealing (IPSA) and hybrid inverse planning optimization (HIPO) algorithms in HDR brachytherapy of cervical cancer
In conclusion, HIPO emerged as the preferred algorithm for interstitial cervical HDR brachytherapy due to improved dose distribution in HR-CTV and plan quality as well.
Authors
- Sunil Choudhary (ORCID: https://orcid.org/0000-0002-0875-809X)
- Ankur Mourya (ORCID: https://orcid.org/0000-0002-8958-2929)
- Abhijit Mandal (ORCID: https://orcid.org/0000-0001-5626-1072)
- Ankita Singh (ORCID: https://orcid.org/0000-0002-5886-5969)
- Lalit Aggarwal
- Syed Mohamed Shajid
- V. Gogul Priean
Institutions
- Netaji Subhash Chandra Bose Medical College (IN)
- Cancer Institute (WIA) (IN)
- Institute of Medical Sciences (IN)
- Banaras Hindu University (IN)
Publication Details
- Journal
- Journal of Cancer Research and Therapeutics
- Published
- 2025-04-01
- DOI
- https://doi.org/10.4103/jcrt.jcrt_1335_24
- Citations
- 1
- Primary Topic
- Endometrial and Cervical Cancer Treatments
- Type
- article
- Field-Weighted Citation Impact
- 2.06