Evaluation of Peri‐Implant Bone Repair of Commercially Pure Titanium or Titanium‐Aluminum‐Vanadium Alloy Implants With or Without Laser‐Modified Surface

To evaluate the peri-implant bone repair of implants manufactured from commercially pure titanium (cp-Ti) or titanium-aluminum-vanadium alloy (Ti-6Al-4 V) with machined (MS) or laser-modified (LS) surfaces. Implants (n = 192) were installed in the tibias of 96 rats and divided according to the implant installed: (1) cpMS: cp-Ti with an MS surface, (2) cpLS: cp-Ti with an LS surface, (3) alloyMS: Ti-6Al-4 V with an MS surface, and (4) alloyLS: Ti-6Al-4 V with an LS surface. Scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analysis was performed prior to implant placement. At 14, 21, and 42 days, biomechanical analysis, SEM-EDX of the removed implants, and measurement of the percentage of bone-implant contact (%BIC) and neoformed bone area (%NBA) were performed. At 42 days, the mineral apposition rate (MAR) and bone dynamics were analyzed. At 14 and 21 days, the alloyLS group showed higher removal torque values than cpLS (p < 0.05). For SEM-EDX, the cpLS and alloyLS groups showed surfaces covered by bone tissue and higher peaks of calcium and phosphorus. No statistical differences were observed for %BIC, and at 14 days, a higher %NBA was found for alloyLS than cpLS (p < 0.05). At 42 days, in bone dynamics, alloyLS showed a higher amount of calcein compared to cpLS (p < 0.05), and higher MAR values were observed for cpLS (p < 0.05). The alloyLS group promoted accelerated peri-implant bone repair at 14 and 21 days. However, at 42 days, cpLS surpassed the values of removal torque, %BIC, %NBA, bone dynamics, and MAR.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2025-07-01
DOI
https://doi.org/10.1002/jbm.b.35610
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Peri‐Implant Bone Repair of Commercially Pure Titanium or Titanium‐Aluminum‐Vanadium Alloy Implants With or Without Laser‐Modified Surface

Fernando Pozzi Semeghini Guastaldi, Pier Paolo Poli, Ana Flávia Piquera Santos, Letícia Gabriella de Souza Rodrigues et al.
1 citations
Journal of Biomedical Materials Research Part B Applied Biomaterials
Bone Tissue Engineering Materials
0.67
article

Evaluation of Peri‐Implant Bone Repair of Commercially Pure Titanium or Titanium‐Aluminum‐Vanadium Alloy Implants With or Without Laser‐Modified Surface

Fernando Pozzi Semeghini Guastaldi, Pier Paolo Poli, Ana Flávia Piquera Santos, Letícia Gabriella de Souza Rodrigues, Luis Fernando Alves da Silva, Rodolfo Debone Piazza, Henrique Hadad, Laís Kawamata de Jesus, Antônio Carlos Guastaldi, Carlo Maiorana, Francisley Ávila Souza, Thallita Pereira Queiroz, Roberta Okamoto
article en
1 citations

Abstract

To evaluate the peri-implant bone repair of implants manufactured from commercially pure titanium (cp-Ti) or titanium-aluminum-vanadium alloy (Ti-6Al-4 V) with machined (MS) or laser-modified (LS) surfaces. Implants (n = 192) were installed in the tibias of 96 rats and divided according to the implant installed: (1) cpMS: cp-Ti with an MS surface, (2) cpLS: cp-Ti with an LS surface, (3) alloyMS: Ti-6Al-4 V with an MS surface, and (4) alloyLS: Ti-6Al-4 V with an LS surface. Scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analysis was performed prior to implant placement. At 14, 21, and 42 days, biomechanical analysis, SEM-EDX of the removed implants, and measurement of the percentage of bone-implant contact (%BIC) and neoformed bone area (%NBA) were performed. At 42 days, the mineral apposition rate (MAR) and bone dynamics were analyzed. At 14 and 21 days, the alloyLS group showed higher removal torque values than cpLS (p < 0.05). For SEM-EDX, the cpLS and alloyLS groups showed surfaces covered by bone tissue and higher peaks of calcium and phosphorus. No statistical differences were observed for %BIC, and at 14 days, a higher %NBA was found for alloyLS than cpLS (p < 0.05). At 42 days, in bone dynamics, alloyLS showed a higher amount of calcein compared to cpLS (p < 0.05), and higher MAR values were observed for cpLS (p < 0.05). The alloyLS group promoted accelerated peri-implant bone repair at 14 and 21 days. However, at 42 days, cpLS surpassed the values of removal torque, %BIC, %NBA, bone dynamics, and MAR.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(7)
University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Massachusetts General Hospital (US), Centro Universitário de Araraquara (BR), Universidade Estadual Paulista (Unesp) (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 30%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.