Comparison of the Manual And Otomated System For Microscopic Examination of Urine

Nowadays, it is quite common in medical laboratories to use devices with a fixed slide system under the microscope objective for microscopic examination of urine, which eliminates the hassle of preparing slides between slides for microscopic examination of urine and standardizes the sediment volume. Objective: In our study, we compared the microscopic analysis results obtained with the Sysmex UF-100 device, one of the fully automated systems, and the DiaSys R/S 2003 device with a fixed slide (OSA) system. We aimed to identify the parameters that can be used interchangeably and give results that support each other, to reveal inconsistent results, if any, and to determine the method that we can obtain more quantitatively consistent results. Method: The data obtained from the analysis results for both systems were analyzed into the SPSS 22.0 program. Descriptive values were expressed as number (n), mean (Mean), standard deviation (SD). Continuous variables were compared with the Wicoxan Signed Ranks test because they did not fit the normal distribution. p < 0.05 was considered statistically significant. Results: According to the findings between UF-100 and OSA, we found that the analysis results for erythrocyte, leukocyte, epithelial cell parameters were consistent with each other, but not for cilia (cast). Keywords: UF-100, DiaSys R/S 2003, urine analysis, manual microscopy

Authors

Institutions

Publication Details

Journal
Gaziantep Islam Science and Technology University
Published
2025-07-05
DOI
https://doi.org/10.46871/eams.1513916
Primary Topic
Urinary Tract Infections Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Manual And Otomated System For Microscopic Examination of Urine

Bağnu Dündar, Hatıce Nur Halıpcı Topsakal, Fatma Bozkurt
Gaziantep Islam Science and Technology University
Urinary Tract Infections Management
article

Comparison of the Manual And Otomated System For Microscopic Examination of Urine

Bağnu Dündar, Hatıce Nur Halıpcı Topsakal, Fatma Bozkurt
article en

Abstract

Nowadays, it is quite common in medical laboratories to use devices with a fixed slide system under the microscope objective for microscopic examination of urine, which eliminates the hassle of preparing slides between slides for microscopic examination of urine and standardizes the sediment volume. Objective: In our study, we compared the microscopic analysis results obtained with the Sysmex UF-100 device, one of the fully automated systems, and the DiaSys R/S 2003 device with a fixed slide (OSA) system. We aimed to identify the parameters that can be used interchangeably and give results that support each other, to reveal inconsistent results, if any, and to determine the method that we can obtain more quantitatively consistent results. Method: The data obtained from the analysis results for both systems were analyzed into the SPSS 22.0 program. Descriptive values were expressed as number (n), mean (Mean), standard deviation (SD). Continuous variables were compared with the Wicoxan Signed Ranks test because they did not fit the normal distribution. p < 0.05 was considered statistically significant. Results: According to the findings between UF-100 and OSA, we found that the analysis results for erythrocyte, leukocyte, epithelial cell parameters were consistent with each other, but not for cilia (cast). Keywords: UF-100, DiaSys R/S 2003, urine analysis, manual microscopy

Gaziantep Islam Science and Technology UniversityVol. 6(2)
Istanbul Medipol University (TR), Atlas Üniversitesi, Istanbul Arel University (TR), Istanbul Commerce University (TR), Istanbul University (TR)
Openalex Percentile: Top 76%
Urinary Tract Infections Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of the Manual And Otomated System For Microscopic Examination of Urine — Bağnu Dündar, Hatıce Nur Halıpcı Topsakal, et al. · Gaziantep Islam Science and Technology University (2025) | TGRS Research Map | TGRS