Role of transthoracic ultrasound in assessment of successful weaning from mechanical ventilation at respiratory ICU

Background Transthoracic ultrasonography (US) is recently introduced in the ICU to predict weaning from invasive mechanical ventilation (MV) by assessment of diaphragmatic parameters, lung US score, and assessment of cardiac function. Aim The objective of this investigation was to assess the accuracy of transthoracic US in identifying the parameters that are indicative of weaning success from invasive MV. Patients and methods This cross-sectional observational study was implemented on 30 patients in the ICU receiving invasive MV. Lung, diaphragmatic, and cardiac US were applied to each patient, and their diagnostic accuracy in anticipating the weaning success was evaluated. Results Thirty patients were examined; 20 were successfully extubated, while 10 were unsuccessful. With a cut-off value more than or equal to 63% and 1.35 cm, the diaphragmatic thickness fraction and diaphragmatic excursion had a sensitivity of 70 and 100%, specificity of 80 and 100%, and accuracy of 73 and 100%, respectively, for predicting the success of weaning. In contrast, the ejection fraction % demonstrated a sensitivity, specificity, and accuracy of 80% with a cut-off value of more than or equal to 52.2% also the lung US score exhibited a sensitivity of 80%, specificity of 70%, and accuracy of 77% with a cut-off value of less than 11, while inferior vena cava distensibility index shows no role in the prediction of weaning success with P value 0.277. Conclusion A dependable, noninvasive, and convenient method for predicting weaning success has been demonstrated by transthoracic US in the evaluation of lung score, diaphragmatic function, and cardiac function.

Authors

Institutions

Publication Details

Journal
Egyptian Journal of Chest Diseases and Tuberculosis
Published
2025-07-01
DOI
https://doi.org/10.4103/ecdt.ecdt_18_25
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of transthoracic ultrasound in assessment of successful weaning from mechanical ventilation at respiratory ICU

Amal A. El-Koa, Mohammed A. Agha, Hany Elgamal, Amal A. Abd El-Aziz et al.
Egyptian Journal of Chest Diseases and Tuberculosis
Ultrasound in Clinical Applications
article

Role of transthoracic ultrasound in assessment of successful weaning from mechanical ventilation at respiratory ICU

Amal A. El-Koa, Mohammed A. Agha, Hany Elgamal, Amal A. Abd El-Aziz, Mahmoud M. El-Habashy
article en

Abstract

Background Transthoracic ultrasonography (US) is recently introduced in the ICU to predict weaning from invasive mechanical ventilation (MV) by assessment of diaphragmatic parameters, lung US score, and assessment of cardiac function. Aim The objective of this investigation was to assess the accuracy of transthoracic US in identifying the parameters that are indicative of weaning success from invasive MV. Patients and methods This cross-sectional observational study was implemented on 30 patients in the ICU receiving invasive MV. Lung, diaphragmatic, and cardiac US were applied to each patient, and their diagnostic accuracy in anticipating the weaning success was evaluated. Results Thirty patients were examined; 20 were successfully extubated, while 10 were unsuccessful. With a cut-off value more than or equal to 63% and 1.35 cm, the diaphragmatic thickness fraction and diaphragmatic excursion had a sensitivity of 70 and 100%, specificity of 80 and 100%, and accuracy of 73 and 100%, respectively, for predicting the success of weaning. In contrast, the ejection fraction % demonstrated a sensitivity, specificity, and accuracy of 80% with a cut-off value of more than or equal to 52.2% also the lung US score exhibited a sensitivity of 80%, specificity of 70%, and accuracy of 77% with a cut-off value of less than 11, while inferior vena cava distensibility index shows no role in the prediction of weaning success with P value 0.277. Conclusion A dependable, noninvasive, and convenient method for predicting weaning success has been demonstrated by transthoracic US in the evaluation of lung score, diaphragmatic function, and cardiac function.

Egyptian Journal of Chest Diseases and TuberculosisVol. 74(3)
Menoufia University (EG)
Openalex Percentile: Top 80%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Role of transthoracic ultrasound in assessment of successful weaning from mechanical ventilation at respiratory ICU — Amal A. El-Koa, Mohammed A. Agha, et al. · Egyptian Journal of Chest Diseases and Tuberculosis (2025) | TGRS Research Map | TGRS