Thermal analysis of a double U-loop vertical ground heat exchanger for a solar-assisted ground source heat pump

• Comparative analysis of conventional GSHPs and a SAGSHP using a double U-loop. • A novel double U-loop GHE is proposed and compared with the conventional type. • Performance analysis conducted under dynamic conditions and a realistic building load. • The proposed double U-loop configuration shows superior performance. • No significant effect of shank spacing and borehole diameter. Among the challenges to the wider adoption of ground-source heat pumps is the ground thermal imbalance caused by significantly different heating and cooling loads in cold climate regions. To address this, this study investigates the performance of a solar-assisted ground source heat pump (SAGSHP) system for space heating and cooling in a cold climate. The system includes a 150 m deep and 0.15 m diameter ground heat exchanger (GHE) with two U-loop pipes separately connected to the solar collector and the heat pump. The effect of solar collector size and GHE parameters on the operational performance of a double U-loop SAGSHP is examined using a validated finite-volume computational fluid dynamics model. Moreover, a new double U-loop GHE configuration is proposed, and its performance is evaluated in comparison with the conventional double U-loop GHE configuration. The findings of this study indicate an up to 29% increment in the coefficient of performance of the system while maintaining a relatively constant ground temperature. For the conventional double U-loop, results further show that changes in the shank spacing for the same borehole diameter have no significant influence on the heat pump performance. However, increasing the borehole diameter results in lower peak and higher minimum temperatures of the heat pump entering fluid. The proposed inline double U-loop configuration shows superior performance over the conventional double U-loop with an additional heating COP of 0.14 and heat pump annual energy saving of 4%. This study demonstrates the potential for optimal performance improvement of SAGSHPs with the proposed inline configuration in cold climates.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2025-07-05
DOI
https://doi.org/10.1016/j.tsep.2025.103837
Citations
1
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal analysis of a double U-loop vertical ground heat exchanger for a solar-assisted ground source heat pump

Nicholas Fry, A. A. Mohamad, Roman Shor, Aggrey Mwesigye et al.
1 citations
Thermal Science and Engineering Progress
Geothermal Energy Systems and Applications
0.36
article

Thermal analysis of a double U-loop vertical ground heat exchanger for a solar-assisted ground source heat pump

Nicholas Fry, A. A. Mohamad, Roman Shor, Aggrey Mwesigye, Philip Adebayo
article en
1 citations

Abstract

• Comparative analysis of conventional GSHPs and a SAGSHP using a double U-loop. • A novel double U-loop GHE is proposed and compared with the conventional type. • Performance analysis conducted under dynamic conditions and a realistic building load. • The proposed double U-loop configuration shows superior performance. • No significant effect of shank spacing and borehole diameter. Among the challenges to the wider adoption of ground-source heat pumps is the ground thermal imbalance caused by significantly different heating and cooling loads in cold climate regions. To address this, this study investigates the performance of a solar-assisted ground source heat pump (SAGSHP) system for space heating and cooling in a cold climate. The system includes a 150 m deep and 0.15 m diameter ground heat exchanger (GHE) with two U-loop pipes separately connected to the solar collector and the heat pump. The effect of solar collector size and GHE parameters on the operational performance of a double U-loop SAGSHP is examined using a validated finite-volume computational fluid dynamics model. Moreover, a new double U-loop GHE configuration is proposed, and its performance is evaluated in comparison with the conventional double U-loop GHE configuration. The findings of this study indicate an up to 29% increment in the coefficient of performance of the system while maintaining a relatively constant ground temperature. For the conventional double U-loop, results further show that changes in the shank spacing for the same borehole diameter have no significant influence on the heat pump performance. However, increasing the borehole diameter results in lower peak and higher minimum temperatures of the heat pump entering fluid. The proposed inline double U-loop configuration shows superior performance over the conventional double U-loop with an additional heating COP of 0.14 and heat pump annual energy saving of 4%. This study demonstrates the potential for optimal performance improvement of SAGSHPs with the proposed inline configuration in cold climates.

Thermal Science and Engineering ProgressVol. 64
University of Calgary (CA), Texas A&M University (US)
University of Calgary, Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 42%
Geothermal Energy Systems and Applications
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.