Peak frequency analysis of the straight-shaped pulsed field ablation catheter during cavotricuspid isthmus ablation

In recent years, pulsed field ablation (PFA) catheter-based treatment has become increasingly prevalent, with applications now extending beyond pulmonary vein isolation (PVI). The most widely used PFA catheter in the market is the Farapulse (Boston Scientific, Marlborough, MA, USA), which has been reported to demonstrate both high efficacy and safety.1 However, several studies have highlighted the potential risk of inducing coronary artery vasospasm.2 This risk is particularly pronounced when performing PFA applications near coronary arteries, such as in cavotricuspid isthmus (CTI) or mitral valve isthmus regions.

Authors

Institutions

Publication Details

Journal
HeartRhythm Case Reports
Published
2025-07-05
DOI
https://doi.org/10.1016/j.hrcr.2025.06.032
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peak frequency analysis of the straight-shaped pulsed field ablation catheter during cavotricuspid isthmus ablation

Masashi Kato, Takafumi Yokomatsu, Tetsuma Kawaji, Misaki Naka et al.
HeartRhythm Case Reports
Cardiac Arrhythmias and Treatments
article

Peak frequency analysis of the straight-shaped pulsed field ablation catheter during cavotricuspid isthmus ablation

Masashi Kato, Takafumi Yokomatsu, Tetsuma Kawaji, Misaki Naka, Saki Yamano
article en

Abstract

In recent years, pulsed field ablation (PFA) catheter-based treatment has become increasingly prevalent, with applications now extending beyond pulmonary vein isolation (PVI). The most widely used PFA catheter in the market is the Farapulse (Boston Scientific, Marlborough, MA, USA), which has been reported to demonstrate both high efficacy and safety.1 However, several studies have highlighted the potential risk of inducing coronary artery vasospasm.2 This risk is particularly pronounced when performing PFA applications near coronary arteries, such as in cavotricuspid isthmus (CTI) or mitral valve isthmus regions.

HeartRhythm Case ReportsVol. 11(9)
Kyoto University (JP), Mitsubishi Kyoto Hospital (JP)
Japan Lifeline, Medtronic Japan
Openalex Percentile: Top 73%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Peak frequency analysis of the straight-shaped pulsed field ablation catheter during cavotricuspid isthmus ablation — Masashi Kato, Takafumi Yokomatsu, et al. · HeartRhythm Case Reports (2025) | TGRS Research Map | TGRS