Aerosol Delivery to an Adult Model via High-Flow Nasal Cannula with Inspiration-Synchronized Small-Particle Vibrating Mesh Nebulizer

<b><i>Background:</i></b> Aerosol delivery via high-flow nasal cannula (HFNC) with an inspiration-synchronized vibrating mesh nebulizer (VMN) yielded higher inhaled doses than with a continuous VMN. Recently, a prototype VMN generating aerosol particles <3 µm improved aerosol delivery during invasive ventilation in adult and pediatric models, outperforming the conventional VMN. However, the effects of inspiration-synchronized small-particle VMN during HFNC remain unknown. <b><i>Methods:</i></b> An adult manikin was connected to a dual-chamber lung model driven by a ventilator to simulate spontaneous breathing. An HFNC system was utilized with gas flows at 15, 30, and 60 L/min with temperature at 37°C. Both small-particle and conventional VMNs were tested in inspiration-synchronized and continuous modes, with placements at the humidifier inlet and near the nasal cannula. Each experiment involved delivering 1 mL of albuterol (2.5 mg/mL) and was repeated five times. A collecting filter placed at the trachea captured aerosol, which was then eluted and assayed with UV spectrophotometry (276 nm). <b><i>Results:</i></b> When VMN was placed near the nasal cannula, inspiration-synchronized VMN consistently delivered greater inhaled doses compared with continuous VMN, regardless of aerosol particle sizes or HFNC flows (all <i>p</i> < 0.05). When positioned at the humidifier inlet, continuous VMN yielded higher inhaled doses than inspiration-synchronized VMN at 30 and 60 L/min but lower inhaled doses at 15 L/min (all <i>p</i> < 0.05). In the inspiration-synchronized mode, the small-particle VMN delivered greater inhaled doses at HFNC flows of 15 and 30 L/min than the conventional VMN, independent of nebulizer placements (all <i>p</i> < 0.05). The highest inhaled dose was observed with the inspiration-synchronized VMN placed near the nasal cannula and the continuous VMN placed at the humidifier inlet. <b><i>Conclusions:</i></b> In a model of adult transnasal aerosol delivery, the inspiration-synchronized VMN delivered a higher inhaled dose than the continuous VMN when placed near the nasal cannula. The small-particle VMN offers potential for further improvement in aerosol delivery.

Authors

Institutions

Publication Details

Journal
Journal of Aerosol Medicine and Pulmonary Drug Delivery
Published
2025-07-04
DOI
https://doi.org/10.1089/jamp.2025.0005
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aerosol Delivery to an Adult Model via High-Flow Nasal Cannula with Inspiration-Synchronized Small-Particle Vibrating Mesh Nebulizer

Jie Li, James B. Fink, Osama Alanazi
Journal of Aerosol Medicine and Pulmonary Drug Delivery
Inhalation and Respiratory Drug Delivery
article

Aerosol Delivery to an Adult Model via High-Flow Nasal Cannula with Inspiration-Synchronized Small-Particle Vibrating Mesh Nebulizer

Jie Li, James B. Fink, Osama Alanazi
article en

Abstract

<b><i>Background:</i></b> Aerosol delivery via high-flow nasal cannula (HFNC) with an inspiration-synchronized vibrating mesh nebulizer (VMN) yielded higher inhaled doses than with a continuous VMN. Recently, a prototype VMN generating aerosol particles <3 µm improved aerosol delivery during invasive ventilation in adult and pediatric models, outperforming the conventional VMN. However, the effects of inspiration-synchronized small-particle VMN during HFNC remain unknown. <b><i>Methods:</i></b> An adult manikin was connected to a dual-chamber lung model driven by a ventilator to simulate spontaneous breathing. An HFNC system was utilized with gas flows at 15, 30, and 60 L/min with temperature at 37°C. Both small-particle and conventional VMNs were tested in inspiration-synchronized and continuous modes, with placements at the humidifier inlet and near the nasal cannula. Each experiment involved delivering 1 mL of albuterol (2.5 mg/mL) and was repeated five times. A collecting filter placed at the trachea captured aerosol, which was then eluted and assayed with UV spectrophotometry (276 nm). <b><i>Results:</i></b> When VMN was placed near the nasal cannula, inspiration-synchronized VMN consistently delivered greater inhaled doses compared with continuous VMN, regardless of aerosol particle sizes or HFNC flows (all <i>p</i> < 0.05). When positioned at the humidifier inlet, continuous VMN yielded higher inhaled doses than inspiration-synchronized VMN at 30 and 60 L/min but lower inhaled doses at 15 L/min (all <i>p</i> < 0.05). In the inspiration-synchronized mode, the small-particle VMN delivered greater inhaled doses at HFNC flows of 15 and 30 L/min than the conventional VMN, independent of nebulizer placements (all <i>p</i> < 0.05). The highest inhaled dose was observed with the inspiration-synchronized VMN placed near the nasal cannula and the continuous VMN placed at the humidifier inlet. <b><i>Conclusions:</i></b> In a model of adult transnasal aerosol delivery, the inspiration-synchronized VMN delivered a higher inhaled dose than the continuous VMN when placed near the nasal cannula. The small-particle VMN offers potential for further improvement in aerosol delivery.

Journal of Aerosol Medicine and Pulmonary Drug DeliveryVol. 38(6)
Rush University (US), King Khalid University (SA)
Zero hunger
Openalex Percentile: Top 74%
Inhalation and Respiratory Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.