Building design requirements for multi‐hazard protection

Abstract Blast resistant buildings have traditionally been quantified by the ability to resist blast loads for a prescribed level of structural damage. Focus has been placed on the structural performance (i.e., building response) without fully correlating this to occupant vulnerability. Fire and toxic material hazards and their impact on building occupants is often overlooked, resulting in buildings that do not comply with the full intent of API's Recommended Practices 752 and 753 (API RP 752/753). The definition of occupant vulnerability, per API RP 752/753, is the “portion of occupants that could potentially experience a life‐threatening injury or fatality if a potential event were to occur.” As summarized in the fourth edition of API RP 752, “owners/operators should understand and document the basis for the correlation [between building damage and occupant vulnerability] and assess its applicability.”

Authors

Institutions

Publication Details

Journal
Process Safety Progress
Published
2025-07-04
DOI
https://doi.org/10.1002/prs.70001
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Building design requirements for multi‐hazard protection

Thomas J. Mander, Karen R. Vilas
Process Safety Progress
Structural Response to Dynamic Loads
article

Building design requirements for multi‐hazard protection

Thomas J. Mander, Karen R. Vilas
article en

Abstract

Abstract Blast resistant buildings have traditionally been quantified by the ability to resist blast loads for a prescribed level of structural damage. Focus has been placed on the structural performance (i.e., building response) without fully correlating this to occupant vulnerability. Fire and toxic material hazards and their impact on building occupants is often overlooked, resulting in buildings that do not comply with the full intent of API's Recommended Practices 752 and 753 (API RP 752/753). The definition of occupant vulnerability, per API RP 752/753, is the “portion of occupants that could potentially experience a life‐threatening injury or fatality if a potential event were to occur.” As summarized in the fourth edition of API RP 752, “owners/operators should understand and document the basis for the correlation [between building damage and occupant vulnerability] and assess its applicability.”

Process Safety ProgressVol. 44(3)
Baker Engineering and Risk Consultants (United States) (US)
Openalex Percentile: Top 83%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.