Abstract Introduction Parkinson’s disease (PD) is an age-related neurological condition characterised by bradykinesia, tremor, and postural instability. Weight loss within the first year of diagnosis is associated with poor prognosis. Studies suggest that if older adults lose skeletal muscle, their risk of falls and related injuries increases. Therefore, measures of body composition (e.g. muscle, fat) are important in PD, where the risk of falls is high. Established body composition analysis equipment is bulky and only used in research settings. We tested the reliability of a portable SECA mBCA 525 device that has not been validated in PD. Method We recruited 19 participants from Movement Disorder Clinics, with 11 household controls. Participants consented to body composition analysis using a SECA mBCA 525 device. It passes a mild electrical current between adhesive electrodes on the hands and feet to determine tissue impedance. Proprietary algorithms then use the impedance and manually collected data (weight, height, waist circumference and reported activity level) to estimate fat, lean, and water mass (kilograms). We performed this process at two visits a month apart to determine test–retest reliability. Results We collected data from 24 participants: 10/11 control and 14/19 PD participants. All five PD participants with SECA data collection ‘failures’ had rest tremor. However, tremor amplitude was the same as the whole group average (mean 1.6, standard deviation 1.9 vs mean 1.6, standard deviation 1.2 for the whole group). There were no significant differences between estimates of lean- and fat mass between trials 1 and 2 (Bland–Altman plot and linear regression, p > 0.05). Conclusions The SECA mBCA 525 portable bio-impedance analysis device had good test–retest reliability for assessing lean- and fat mass in subjects with and without PD. However, data collection ‘failures’, which may be due to limb tremor, limit its usefulness in studies of people with PD.

Authors

Institutions

Publication Details

Journal
Age and Ageing
Published
2025-07-01
DOI
https://doi.org/10.1093/ageing/afaf133.103
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3162 Reliability and repeatability of a portable bio-impedance measurement device in early Parkinson's disease

Isobel Sleeman, Allyson M Pollock, Kristina Paley, Phyo Kyaw Myint et al.
1 links
Age and Ageing
Muscle activation and electromyography studies
article

3162 Reliability and repeatability of a portable bio-impedance measurement device in early Parkinson's disease

Isobel Sleeman, Allyson M Pollock, Kristina Paley, Phyo Kyaw Myint, A D MacLeod
article en

Abstract

Abstract Introduction Parkinson’s disease (PD) is an age-related neurological condition characterised by bradykinesia, tremor, and postural instability. Weight loss within the first year of diagnosis is associated with poor prognosis. Studies suggest that if older adults lose skeletal muscle, their risk of falls and related injuries increases. Therefore, measures of body composition (e.g. muscle, fat) are important in PD, where the risk of falls is high. Established body composition analysis equipment is bulky and only used in research settings. We tested the reliability of a portable SECA mBCA 525 device that has not been validated in PD. Method We recruited 19 participants from Movement Disorder Clinics, with 11 household controls. Participants consented to body composition analysis using a SECA mBCA 525 device. It passes a mild electrical current between adhesive electrodes on the hands and feet to determine tissue impedance. Proprietary algorithms then use the impedance and manually collected data (weight, height, waist circumference and reported activity level) to estimate fat, lean, and water mass (kilograms). We performed this process at two visits a month apart to determine test–retest reliability. Results We collected data from 24 participants: 10/11 control and 14/19 PD participants. All five PD participants with SECA data collection ‘failures’ had rest tremor. However, tremor amplitude was the same as the whole group average (mean 1.6, standard deviation 1.9 vs mean 1.6, standard deviation 1.2 for the whole group). There were no significant differences between estimates of lean- and fat mass between trials 1 and 2 (Bland–Altman plot and linear regression, p > 0.05). Conclusions The SECA mBCA 525 portable bio-impedance analysis device had good test–retest reliability for assessing lean- and fat mass in subjects with and without PD. However, data collection ‘failures’, which may be due to limb tremor, limit its usefulness in studies of people with PD.

Age and AgeingVol. 54(Supplement_2)
University of Aberdeen (GB)
Openalex Percentile: Top 85%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.