Evaluating Fault Detection Techniques in Real Electrical Transformers: A Comparative Case of Study

Transformers are integral to the reliability of electrical networks, necessitating robust diagnostic methods for fault detection. This study conducts a comparative evaluation of three fault detection techniques using real-world data from distribution transformers. The methods analyzed include differential current analysis, correlation-based techniques, and flux linkage increments. Results demonstrate that differential current analysis exhibits the highest sensitivity (93.33\%), detecting faults at 4.41\% of the short-circuit current. Correlation-based methods follow with 86.67\% sensitivity, while flux linkage increments offer lower sensitivity but robust performance at high current levels. This comparative analysis provides actionable insights for enhancing transformer reliability through effective monitoring strategies.

Authors

Institutions

Publication Details

Journal
Statistics Optimization & Information Computing
Published
2025-06-12
DOI
https://doi.org/10.19139/soic-2310-5070-2446
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Fault Detection Techniques in Real Electrical Transformers: A Comparative Case of Study

Santiago Guzman-Arteaga, Santiago Gómez-Arango, Daniel Sanin-Villa, María del Pilar Buitrago-Villada
Statistics Optimization & Information Computing
Electrical Fault Detection and Protection
article

Evaluating Fault Detection Techniques in Real Electrical Transformers: A Comparative Case of Study

Santiago Guzman-Arteaga, Santiago Gómez-Arango, Daniel Sanin-Villa, María del Pilar Buitrago-Villada
article en

Abstract

Transformers are integral to the reliability of electrical networks, necessitating robust diagnostic methods for fault detection. This study conducts a comparative evaluation of three fault detection techniques using real-world data from distribution transformers. The methods analyzed include differential current analysis, correlation-based techniques, and flux linkage increments. Results demonstrate that differential current analysis exhibits the highest sensitivity (93.33\%), detecting faults at 4.41\% of the short-circuit current. Correlation-based methods follow with 86.67\% sensitivity, while flux linkage increments offer lower sensitivity but robust performance at high current levels. This comparative analysis provides actionable insights for enhancing transformer reliability through effective monitoring strategies.

Statistics Optimization & Information ComputingVol. 14(1)
Universidad Nacional de Colombia (CO), Instituto Tecnológico Metropolitano (CO), Universidad EAFIT (CO)
Openalex Percentile: Top 86%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.